User's Manual

CHAPTER 5 ND-70185 (E)
Page 90
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3: ANNDL/AMND
Assign the necessary number of digits using the ANNDL or the AMND command depending on the
route data.
When the ARTD command OSGS is 2 (Second Dial Tone), use the ANNDL (Necessary Digits
Data) command.
RT=100 OG NND=12
RT=200 OG NND=12
When the ARTD command OSGS is 4/6/7 (Sender Immediate Start/Sender Delay Dial Start/
Sender Wink Start), use the AMND command.
DC=9 MND=12
STEP 4: ARSCN
Assign the Route Restriction Class (RSC) that allows RRIs for the external trunk route. The same
route restriction data must be assigned for each node.
7.1.3 LCR/LCRS
A procedure for assigning LCR/LCRS access code is explained using the following example.
Figure 5-38 Example of LCR/LCRS
STN (C)
... ... ... ... ...
... ... ... ... ...
... ... ... ... ...
... ... ... ... ...
Node C
PSTN
1-202-567-8901
Station C dials
8110-3500
FCCS ACIS
BUSY
FCCS
TLT
Node B
Destination
Node
Node A
LGRT:200
LGRT:10
COT