DATA PROGRAMMING
Assignment of FCH Related Data
Connection Link (for Data)
C_RT: 11
TCL=4 LSG=13
STEP 3: ACTK
Assign the Connection Trunk data for B-ch and D-ch.
Example:
(When using 512kbps (8ch) TS as Connection link)
Connection trunk (B-ch)
C_RT: 10 TK: 1-664 CLENS: LEN for the SDT
Connection Link (D-ch)
C_RT: 11 TK: 1-8 CLENS: LEN for the FCH
C_RT: 11 TK: 9-16 CLENS: LEN for the SDT
Note:
Set the switch on the FCH card depending on the transmission speed.
See “CHAPTER 4 INSTALLATION” for more information on switch settings.
STEP 4: AFCH
Assign the FCCH number for each FCCH.
FCHN: 2 (FCCH number) FCHEN: LEN of FCCH
STEP 5: AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node) FCCH: 1 (with FCCH)
CRT: 10 FCHN: 2
STEP 6: ACAN
Assign the CIC number to the connection trunk.
FPC: 1 FCIC: 1-664 CLENS: LEN of the connection trunk
STEP 7: AFRT
Assign the FCCH Controlled Connection Route data.