User's Manual

CHAPTER 5 ND-70185 (E)
Page 106
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3: MBCT
Unbusy the connection trunk data assigned in the previous step, by using the MBCT command. This
is required for FCH, FGH trunks as well as speech channels.
STEP 4: AFCH
Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assigned
for the FCH circuit card. For the FGH card, FCHN assignment is not necessary.
Figure 5-53 Assignment of FCHN (Example)
Q-sig
PBX
FCH
FGH
DTI
ROUTER
Nail Down Connection
T1
speech
signaling
RT13
RT14
RT1
to CPU
FCHN=1
FCHEN: 000030
FCHN
1
FCHEN
000030
AFCH command display
Note
Note: This setting is a sample.