User's Manual

CHAPTER 6 ND-70185 (E)
Page 140
Revision 3.0
POST INSTALLATION TEST
FCCS Network Connection Test
3.2 ATTCON Connection Test (via FCCS)
Perform the ATTCON connection test, using the following procedure.
3.2.1 ATTCON Call Origination Test
STEP 1: Dial the operator access code (normally “0”), from STN A in Node A.
STEP 2: Confirm that the ATT lamp flashes and ringer sounds at each ATTCON in Node B.
STEP 3: Answer the call by pressing the ATND key.
STEP 4: Confirm the speech condition is sufficient (no noise, not one-party speech, etc.).
STEP 5: Release the call by pressing the CANCEL key.
STEP 6: Replace the handset of STN A in Node A.
3.2.2 ATTCON Call Termination Test
STEP 1: Press a LOOP key on an ATTCON in Node B.
STEP 2: Dial the Telephone Number of STN A.
STEP 3: Confirm the ringer sounds properly at STN A.
STEP 4: Answer the call and confirm the speech condition is sufficient (no noise, not one-way speech, etc.).
STEP 5: The operator at the ATTCON releases the call by pressing the CANCEL key.
STEP 6: Replace the handset of STN A in Node A.
Figure 6-9 ATTCON Connection Test (origination) via FCCS
Check
Check
LC
ATI
FCCS
STN A
ATTCON
Node A (Self-Node) Node B
TELN: 410000
STN: 2000
TELN: Telephone Number STN: Physical Station Number
Operator Access
Code "0"
R
I
N
G
I
N
G