ND-70185 (E) CHAPTER 8
Page 195
Revision 3.0
EX- FCCS
Data Programming
4.2.2 Upgrading CCIS between FUG and IVS2 System to Enhanced CCIS Network
1. To Log-in to All Nodes in EX-FCCS Network
Assign the following data at the NCN of FUG with Centralized MAT for Fusion.
STEP 1: AFUGN
Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number and
Fusion Point Code (FPC) of the NCN within each FUG. Assign the FplUG as the Center by clicking
the check box in the “CENTER” parameter.
STEP 2: AEXFN
Assign the CCH Selection Data by designating all the Fusion Point Code (FPC) and the Point Code
(PC) in the connected Fusion Group.
Note:
Confirm the Centralized MAT can log in to each node here. Reexamine the assigned data if log-in can not
be executed. There may be some error in data setting so far.
FCCS
FCCS
FCCS
FCCS
FCCS
FCCS
FUG (Center FUG)
PC1
FPC1
PC2
FPC2
PC3
FPC3
NCN
IVS System
PC4
IMX
IMX
IMX
CCIS
2
Enhanced CCIS