User's Manual

ND-70185 (E) CHAPTER 5
Page 63
Revision 3.0
DATA PROGRAMMING
Assignment of System Data
STEP 2: ASYDL
Assign the self-Fusion Point Code (self-FPC) at each node. FPC ranges from 1 to 253. Use the ASY-
DL command. (Index 512 b0-b7)
Index 512 self-Fusion Point Code
Assign a unique FPC for each node.
Figure 5-6 Self-FPC Assignment
STEP 3: ASYDL and ASYDN
Assign other system data using the ASYDL/ASYDN command.
When Timing Start is used, assign the following data.
Index 161 b6 : 0/1=-/Timing Start using “#” code
b7 : 0/1=-/Timing Start using “*” code
Index 170 b4 : 0/1=Timing Start out of Service/Timing Start in Service
Note 1
Index 640 Fusion Point Code (FPC) of node providing ATTCON
Note 2
Index 704~735 (ASYDL)
FPC of the node to which ATTCON transfers the Day/Night changeover
information.
Note 3
Assign FPC of a terminating node for House Phone, Off-Hook Alarm and Ring Down (IC) calls from
PSTN. Day/Night information is transferred from the terminating node.
Note 1:
When Timing Start is in service, Called Sub Address for ISDN Network cannot be dialed.
Note 2:
This data is necessary at each node. Assign the self-FPC at the terminating node.
Note 3:
This data is necessary at the node providing ATTCON.
NCN: Network Control Node
LN: Local Node
LN
LN
LN
LN
LN
LN
LN
LN
NCN
1
2
10
11
12
21
22
23
24
This figure shows an example of FPC assignment. Assign a unique FPC for each node.
ASYDL Index 512 (b0-b7)