User's Manual

CHAPTER 5 ND-70185 (E)
Page 76
Revision 3.0
DATA PROGRAMMING
Assignment of Telephone Numbers
STEP 2: ACTK
Assign the connection trunk data of both B-channel and D-channel using the ACTK command. As-
sign the Connection Equipment Number (C_LENS) referring to Figure 5-22 through Figure 5-25.
The ACTK command display should look similar to the following.
Figure 5-22 ACTK Command Display (example)
The mounting location of the FCH, DTI cards can be classified into the following two types.
Regular Density Slot (16-port slot) -See Figure 5-23.
High Density Slot (32-port slot) -See Figure 5-24 and Figure 5-25.
6.1.1 When FCH is mounted in a Extended Density Slot
If the FCH is to be mounted in the Extended Density Slot, the connection trunk should be assigned as
shown in the figures below. If the card’s mounting location is in any of the Slot Nos. 04, 06, 08, or 15,
17, 19, the following extended Group should be used for the Dch trunk: G27, 29, or 31. Figure 5-23
shows an example where the cards are mounted in density Slots 04 or 05.
Figure 5-23 Mounting FCH and DTI Cards in Regular Density Slots
C_RT
C_TK
C_LENS
WRT?
ACTK (Assignment of Connection Trunk Data for Local Data Memory)
Y
10
1
000010
C_RT: Connection Route (1-1023)
C_TK: Connection Trunk (1-4095)
C_LENS: Connection Line Equipment Numbers
PIM
00
02
04
05
06 07 08 09 10 11 12 13 14 15 16 17
18
19
20
21
22
23
12
13
14
15
16
17
18
19
20
21
22
23
00
01
02 04
04
06
06
08
08
10
10
03
05
05
07
07
09
09 11
11
12
13
14
15
16
17
18
19
20
21
22
23
PWR
DPWR
32 Port
16 Port
32 Port
16 Port
FRONT VIEW
example
TSW/MUX
TSW/MUX