User's Manual

CHAPTER 5 ND-70185 (E)
Page 82
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
Figure 5-29 shows a sample data assignment when FCH cards are located in the PIM 0 slot 4 and PIM 2 slot 11.
Figure 5-27 Assignment of FCH Number
The AFCH command display should look similar to the following:
Figure 5-28 AFCH Command Display (example)
NEC
NEAX 2400 IMS
FCHN=2
LENS: 000270
FCHN=1
As an example, data assignment when FCH cards are accommodated in the following slots is shown here.
PIM 0, slot 4 and PIM 2, slot 11
Data Assignment
PIM 0 Slot 04
LENS 011190
PIM 2 Slot 11
FCHN: 2 FCHEN: 01 0 19 0
FCHN: 1 FCHEN: 00 0 27 0
AFCH (Assignment of FCH Number for.....)
Slot No.
Dch (TK1)
Bch (TK23)
Bch (TK1)
Bch (TK8)
Bch (TK9)
Bch (TK16)
Bch (TK17)
20
Dch (TK2)
11
12
Group No.
19
23
22
21
DTI
FCH
Use "odd number" as the Group No. and "Level 0" for the FCHN.
example 2
(High-density slot 11)
example 1
(Regular-density slot 04)
FCHEN
xx x 19 0
MG U
Gr
Lv
Use this LENS.
odd No.
Lv=0
FCH card
PBX
FCHEN
xx x 27 0
MG U
Gr
Lv
Use this LENS.
04
05
01
27
03
00
02
Dch (TK1)
Bch (TK23)
Bch (TK1)
Dch (TK2)
Bch (TK8)
Bch (TK9)
Slot No.
Group No.
FCH
DTI
Extended Group
Untitled - EclipseCmd
File View
Help
AFCH (Assignment of FCCH Number for.....)
FCHN
FCHNEN
WRT?
1
000270
Y
FCHN (1-255)
FCHEN
x x x x x x
MG: 0-7
U: 0-3
Group: 00 - 31
Lv: 0-7
MG
U
Gr
Lv
Note:
Before assigning FCHN, the trunk data must have been assigned using the ACTK command.