Connecting to the Monitoring Device
1. Connect to the Monitor Port using a Net Optics custom LC analyzer cable
2. Connect one side of the twin-duplex ber cable into a RX port on the
monitoring device to view one side of the full-duplex link.
3. Connect the other side of the twin-duplex ber cable into another RX port
on the monitoring device to view the other side of the full-duplex link.
4. Verify that the Tap Monitor Port is cabled to the monitoring device.
5. Repeat steps 1-4 as needed for remaining segements.
Note: ________________________________________________________________
The connectors on the twin-duplex side of the custom analyzer cable contain
RX connections only. The empty TX sides are present to eliminate cabling
errors and should also be connected to the monitoring device
.
______________________________________________________________________
Figure 3: Connecting the Monitoring Device
To Monitoring Device
Splitter Tap HD8Splitter Tap HD8
www.netoptics.com
A B AA BB
OUT IN OUT IN OUT OUT
A B AA
OUT IN OUT IN OUT OUT
A B AA
BB
OUT IN OUT IN OUT
OUT
A B AA BB
OUT IN OUT IN OUT OUT
1 2
4
3