Owner manual

Slide the boot onto the cable.
Solder the wire ends in the order Sleeve, Ring
and Tip.
Position the chuck onto the cable and align
chuck with plugfinger.
Finish the installation by tighten the bushing
onto the connector.
Attention:
If using a cable with O.D. > 5.50 mm [0.216”] break
off marked part of the chuck.
Prepare cable as shown.
Push the cover to the stop position on the shell.
A
B
C
E
F
A
D
B
C
NP2RX
NP3RX
F
E
D
break off
20
[
0.78”
][
0.78”
]
5
[
0.20”
][
0.20”
]
Ring
Tip
3
[
0.12”
][
0.12”
]
8
[
0.32”
][
0.32”
]
10
[
0.39”
][
0.39”
]
Sleeve
4
[
0.16”
][
0.16”
]
20
[
0.78”
][
0.78”
]
10
[
0.39”
][
0.39”
]
NP*RX 1/4” Professional Phone PlugRight-Angle
|