Setup instructions

PowerCon HC
®
Locking 2P+PE AC appliance coupler
Slide bushing and chuck onto the cable
end.
Prepare cable as shown.
Consider excessive length of PE conductor for
slackening.
Strip the wires.
(1) (2)
Less 15 mm please use reducing piece (3).
If cable O.D.:
Assembly Instructions
A
B
A
Cable Connector:
[0.354"]
9mm
Features:
250 Vac, 32 Amp (at ambient temperatures up to 35°C) / 30 Amp for cUR
Cable O.D. 17 mm (general range: 8.0 to 20.0 mm)
Wiring: Cable Connector: Screw-type terminals for stranded wires 6.0 mm (AWG 10)
Chassis Connector: Screw-type terminals for wires 6.0 mm (AWG 10)
2
2
·
·
·
Important Safety Instruction:
Attention: Connector without breaking capacity acc. IEC 61984 - must not be
engaged or disengaged when under load or live.
Insert wires into terminals and
tighten.
Wiring: *
L, N, PE
ATTENTION: Max torque 180 cNm
L
Black
N
White
PE
Green
C
1
2
25 mm 15 mm
C
3
-1-