User Manual

The flexible grounding system, applicable for each channel separately, provides the following
alternatives:
Individual (without grounding clip): Each channel ground (sleeve contact) is connected to the
dedicated ground contact of the incoming 1/4” plug only. This is the standard configuration.
Chassis common (1):
The relevant channel grounds (sleeve contacts; top and bottom row) is connected to the ground
flat tab via grounding clip and chassis.
Chassis top (2):
The dedicated top row channel ground (sleeve contact) is connected to the ground flat tab via
grounding clip and chassis.
Chassis bottom (3):
The dedicated bottom row channel ground (“S” terminal) is connected to the ground flat tab via
grounding clip and chassis.
Rear view Detail:
Ground flat tab to be used with 3/16” (4.8 x 0.8 mm) FASTON receptacle
or to solder the wire.
®
(
FASTON is a trademark of AMP Inc.
)
®
l
l
l
l
The grounding clips are applicable in every electrical configuration.
For electrical configurations please refer to the printed information on the Patch Panel.
S
R
T
SS
R
T
SS
RS
TS
SS
S
R
T
SS
T
R
S
S
S
R
T
SS
R
T
SS
RS
TS
SS
S
R
T
SS
T
R
S
S
S
R
T
SS
R
T
SS
RS
TS
SS
S
R
T
SS
T
R
S
S
1
2
3
grounding clip
(slide onto the print)
2
3
1
Draft. Nr.: BDA 175 Update: 30.03.2010/ 3102M14511
II
Data subject to change without prior notice. 2010 NEUTRIK . ALL RIGHTS RESERVED.©
®
ASSEMBLY INSTRUCTION
www.neutrik.com
NYS-SPP-L1 1/4” Patch Panel - Grounding Variations
|
NEUTRIK AG
NEUTRIK USA Inc.
NEUTRIK UK Ltd.
NEUTRIK
T: F:
T: F:
()
T: F:
T: F:
LI
USA
UK
DE/NL/AT/DK
+423 / 237 24 24 +423 / 232 53 93
+1 732 / 901 9488 +1 732 / 901 9608
+44 1983 / 811441 +44 1983 / 811 439
+49 8131 / 280 890 +49 8131 / 280 830
Vertriebs GmbH
NEUTRIK France
NEUTRIK Tokyo Ltd.
NEUTRIK
NEUTRIK Ningbo CN
FR
JP
HK
T: F:
T: F:
Hong Kong T: F:
T: F :
+33 1 / 4131 6750 +33 1 / 4131 0511
+81 3 / 3663 4733 +81 3 / 3663 4796
+852 / 2687 6055 +852 / 2687 6052
+86 574 882504880 +86 574 88265000
Ltd.
//

Summary of content (1 pages)