Instructions / Assembly

18
Installing Grill on custom built cabinet
10in
10in
1in
MINIMUM 10 SQ IN (65 SQ CM)
OF VENTILATION REQUIRED
MINIMUM 20 SQ IN (130 SQ
CM) OF VENTILATION
REQUIRED.
Back View
NOTE: These illustrations are for reference purpose only. Actual built-in cabinets and installation
may dier.
Layout for Non-combustible enclosure
NON-COMUSTABLE MATERIAL
MINIMUM 20 SQ IN (130 SQ
CM) OF VENTILATION
REQUIRED ON EACH END OF
CABINET.
5"
2.375” Dia
127mm
MAXIMUM
1"
25.4mm
MAXIMUM
W
D
H
PARTITION TO ISOLATE
CYLINDER FROM GRILL
MINIMUM 10 SQ IN (65 SQ CM)
OF VENTILATION REQUIRED ON
EACH END OF CABINET.
Rubber grommet
Note: Avoid abrasion of hose against the
opening. It is recommended to use a rubber
grommet at the opening.
H1
W1
WARNING
The upper vent opening must be at least 20
square inches.
The lower vent opening must be at least 10
square inches.