Instructions / Assembly

25
Gas Connections
WARNING
Never connect a gas line directly to the grill. A pressure regulator must be installed on all gas
equipment. Removing or failing to install the pressure regulator can result in re, and serious
personal injury and will void the warranty. This grill is designed for non-combustible enclosures
only, and must be installed and serviced by a licensed gas tter to local codes.
As indicated on the rating plate, this gas grill is designed to operate with gas supply pressures
of 7” WC for Natural Gas. For installations where the gas supply pressure exceeds these
requirements, a regulator must be installed upstream of the grill’s components. If the gas supply
pressure is lower than these requirements, the unit will be under-red and will not reach the
maximum temperatures. Ensure that the supply line size complies with local and/or national
installation codes.
Rating Plate - Lists model numbers and gas type
Water Column Requirements
MODEL/ MODÈLE
CLASS NO / CATÉGORIE #: 2711 04/84
EQUIPPED FOR USE WITH
CAUTION: THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR USE WITH NATURAL GAS. THIS
GAS GRILL IS DESIGNED TO OPERATE WITH GAS SUPPLY PRESSURE OF 7”WC FOR NATURAL GAS. IF THE
GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS, THE UNIT WILL BE UNDER-FIRED AND
WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE SUPPLY LINE SIZE COMPLIES WITH
LOCAL AND/OR NATIONAL INSTALLATION CODES.
AVERTISSEMENT: CET APPAREIL EST RÉGLÉ ET EXPÉDIÉ POUR UTILISATION AVEC DU GAZ
NATUREL. CE GRIL À GAZ EST CONÇU POUR FONCTIONNER AU GAZ PRESSION D'ALIMENTATION DE 7 ”WC
POUR GAZ NATUREL. SI L'ALIMENTATION DE GAZ LA PRESSION EST INFÉRIEURE À CES EXIGENCES, L'UNITÉ
SERA SOUS-CUIT ET N'ATTAQUE PAS LES TEMPÉRATURES MAXIMALES. ASSUREZ-VOUS QUE LA TAILLE DE LA
LIGNE D'ALIMENTATION EST CONFORME AUX CODES D'INSTALLATION NATIONAUX.
NATURAL GAS / GAZ NATUREL
MFG DATE DE FABRICATION :
MINIMUM CLEARENCE FROM SIDES AND BACK OF UNIT TO COMBUSTIBLE
CONSTRUCTION, 14 INCHES FROM SIDES, AND 18 INCHES FROM BACK.
ONLY FOR INSTALLATION IN A BUILT-IN ENCLOSURE CONSTRUCTED OF
NON-COMBUSTIONABLE MATERIALS OR NEWAGE GRILL CABINETS. SEE
MODELS.
DÉGAGEMENT MINIMAL ENTRE LES PAROIS LATÉRALES ET L'ARRIÈRE
DE L'APPAREIL ET LA CONSTRUCTION COMBUSTIBLE, 14 POUCES À
PARTIR DES PAROIS LATÉRALES ET 18 POUCES À PARTIR DE
L'ARRIÈRE. UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES OU POUR
APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE.
23”/ 584.2 MM
1 3/4”/32 MM
Supplier to APPLY
PRODUCTION CODE STICKER
WARNING: TURN OFF GAS SUPPLY AT MAIN VALVE WHEN NOT IN
USE. IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE CAUSING
DEATH OR SERIOUS INJURY MAY OCCUR.
ATTENTION: COUPER L'ALIMENTATION EN GAZ DE LA VANNE
PRINCIPALE LORSQU'ELLE N'EST PAS UTILISÉE. SI CES INSTRUCTIONS NE SONT
PAS SUIVIES EXACTEMENT, UN INCENDIE CAUSE LA MORT OU DES BLESSURES
GRAVES PEUVENT SURVENIR.
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. DO NOT USE THIS
APPLIANCE UNDER OVERHEAD COMBUSTABLE SURFACES. ONLY FOR
INSTALLATION IN A BUILT-IN ENCLOSURE CONSTRUCTED OF NON-COMBUSTION-
ABLE MATERIALS. / APPAREIL DE CUISINE DE PLEIN AIR- POUR UTILISATION À
L’EXTÉRIEUR SEULEMENT. NE PAS UTILISER CET APPAREIL SOUS UNE SURFACE
COMBUSTIBLE. CONVIENT UNIQUEMENT POUR INSTALLATION DANS UNE
ENCEINTE ENCASTRÉE FAITE DE MATÉRIAUX INCOMBUSTIBLES.
ANS Z21.58-2018•CSA 1.6-2018
Outdoor Cooking Gas Appliances
GRILL PULSE IGNITOR REQUIREMENTS:
INPUT- AA BATTERY
(Rechargeable and Non-Rechargeable)
USC
PERFORMANCE 36” GRILL-
NG
66981
PERFORMANCE 36”GRILL
NG WITH 36”GRILL CART
66279
X
NEWAGE PERFORMANCE 36” GRILL
(NATURAL GAS)
.CNI STCUDORP EGAWEN
ADANAC ,OIRATNO ,NAHGUAV
ENIHC NE EUQIRBAF /ANIHC NI EDAM
Class IIIA-2
111 CREDITVIEW ROAD, 2nd FLOOR
L4L-9T1
4 X 12,000 BTU/ MAIN TUBE BURNERS / BRÛLEURS À
TUBES PRINCIPAUX
NATURAL GAS/ GAZ
NATUREL
ORIFICE SIZES/ GRANDEUR DES ORIFICS
MAIN BURNERS/ BRÛLEUR PRINCIPAL 1.39MM
Fuel
WC Min Under
Full Load
NATURAL GAS 7 in wc (NG)
The rating plate is located in one or more of the following places:
On the back of Grill
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the
grill on any gas other than that for which the grill has been set.
Both the regulator and the manifold orices have been tuned for the type of gas specied on the
rating plate.
All installation and all installation parts must conform to local codes with the National Electrical
Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANS Z223.1/NFPA 54
in the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
The grill is factory set to use natural gas (NG). It is critical that the gas you use matches that which
the grill was set up for. You can verify that by checking the rating plate.