Natural Gas Installation
Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable
run distances for ¾ inch pipe. Failure to meet these minimum requirements may reduce
performance of the grill and any other appliances running on that supply line.
Always keep supply line runs as short as possible.
A gas shut-o valve must be installed in an easily accessible location by a licensed gas tter.
The outdoor cooking gas appliance and its individual shut-o valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in
excess of 0.5 psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by
closing its individual manual shut-o valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Keep threading compound o of the rst two pipe threads to avoid having any small pieces of
compound break loose and clog a burner valve or orice. Do not use threading compound on
any are ttings.
For built-in installations, it is recommended that any exible pipe used be kept as short as possible.
For freestanding units using natural gas, NewAge strongly recommends using a quick disconnect
kit. This Quick Disconnect kit, is included with purchase.
Note:
This product must be installed by a licensed gas tter when installed within the State of
Massachusetts.
Grill Intake
Manifold
Threaded
nipple
Flexible
Corrugated
Gas Hose (Not
Supplied)
Quick
Disconnect
Threaded
nipple
Quick
Disconnect
Coupler
Main shut-off valve
Gas supply line
from meter
Flexible
Gas Hose
This illustration is for reference only
each installation will be different.
WARNING
Only licensed gas tters must perform the required gas tting on NewAge gas appliances.
To ensure satisfactory performance, the gas supply line must be sized to accommodate the total
BTU/h requirements of all the gas-red equipment that will be connected to that line.
In no case should pipe less than 3/4” inside diameter or 1” outside diameter ever be used to
connect this product.