Instructions / Assembly

36
Burner Position and Flame Adjustment
CAUTION
CAUTION
Proper placement of each burner is critical after cleaning they must be centered on the brass
orice, resting level without any rocking. Failure to meet these conditions may cause a very
dangerous condition that can cause personal injury and property damage.
Turn o gas at source and disconnect the unit before servicing. To avoid the possibility of burns,
maintenance should be done only when the grill is cool. A leak test must be performed annually
and whenever any component of the gas train is replaced or gas smell is present.
Gas control knobs should be in the OFF” position, and fuel line should be disconnected from gas
valve manifold. To reduce the chance of FLASHBACK, the procedure below should be followed at
least once a month or when your grill has not been used for an extended period of time.
Proper Flame
Improper Flame
LIGHT BLUE
DARK BLUE
SPUTTERING
FLAME
BURNER
Burner Position
Valve with Orifice
Image 2
Image 1
BURNER PORT
1. Check burner installation by insuring
that the valve orifice body is securely
inserted into the end opening of the
burner tube. (see Image 1)
2. To check for proper flame. Turn burner
on high and compare to (image 2) for
proper flame consistency. If you
observe improper flame behavior then
refer to page 37 for corrective actions.
YELLOW TIPPING
1” (26mm) Flame Height