Installation Guide

19
CORNER INSTALLATION
All products must be allowed to acclimate; removed from boxes and stored flat at the
installation site for a minimum of 48 hours or until properly acclimated prior to
installation. Heat and moisture cause expansion. Best results are obtained by installing
cool, dry product. NextStone does not warrant against gapping caused by expansion
and contraction.
Step 1
Metal Starter Strip - Determine at what height above grade level
you want the panel to sit on. Measure up 2 ¾" from this point and
strike a level line. Attach the top of the starter strip on this line. End
the strip 2" from each side of the corner.
Step 2-Set the Stacked Stone outside corner piece against the
corner and down into the starter strip. Use the screw guides and
place at least 3 screws along the tongue. Place 2 screws in the
right lap side of the panel where indicated. (Fig. 7).
Figure 7
Step 3-Attach the panels working out from each side
of the corner as previously described. (Fig. 8)
Figure 8
Note: There are 4 patterns of the Stacked Stone Outside Corner. 2 Left patterns
and 2 right patterns. Check for numbers on the backside of each corner piece.
They are numbered 1 through 4. Alternate left and right corners with each course
to ensure offsets and to prevent pattern repetition.
STACKED STONE OUTSIDE CORNER