Operation Manual

108
Time Zone: To simplify the correlation of the events with your local time, you can set
your time zone using this drop-down menu. Note that the B264 presents a simplified list,
with standard GMT offsets. Note that standard GMT offsets do not change back and
forth with Daylight Savings; you will need to make this adjustment manually if it is
relevant to you.
Current Time: This field indicates the B264 view of what the current date and time is.
If your frame is not NTP-synchronized, this is useful to figure out “how long ago did this
event happen”.
Clear Log Display: If you click on this button, it clears all log views. This is useful to
quickly identify any new events after the unit has been set up. Note that this action does
not clear the logs stored in non-volatile memory.
The B264 will store up to about 400 kbytes of logs in non-volatile memory. When that limit is
reached, the oldest half of the stored logs will be deleted to make space for new logs.