Operation Manual

72
The picture below shows an example where four audio channels are enabled:
If SCTE 35 injection is enabled in the Advanced Tab VBI/Ancillary Data Insertion, the
following additional indicators are displayed:
SCTE 35 Packets Injected: shows a count of how many SCTE 35 packets have been
successfully injected in the transport stream for this encoder. Successful SCTE 35
injections are also logged, see the Admin Event Log Tab.
SCTE 35 Packets Dropped: if there are too many SCTE 104 messages, it may not be
possible to insert all the SCTE 35 packets due to internal limitations in the B264. The
B264 can insert up to 10 SCTE 35 packets per second, which is sufficient for all usual ad
insertion applications. If this indicator is nonzero, contact Niagara Video.
SCTE 104 Errors: shows a count of SCTE 104 errors in the incoming signal. A nonzero
count indicates that the device upstream of the B264 is non-compliant. Contact the
vendor of that equipment.
If HTTP Live Streaming is selected in the Encoder Connections Tab, four more indicators are
added to the status area: