Installation Guide

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com July 15, 2020 5:06 PM rev 1.0
T6CS LED TROFFER
INSTALLATION INSTRUCTIONS
To reduce the risk of death, personal injury or property, damage from re, electric shock, falling parts, cuts/abrasions, and other hazards read all
warnings and instructions included with and on the xture box and all xture labels.
Commercial installation, service and maintenance of luminaires should be performed by a qualied licensed electrician.
DO NOT INSTALL DAMAGED PRODUCT
WARNING: RISK OF ELECTRIC SHOCK
Turn o the electrical power at fuse or circuit breaker box before wiring xture to power supply.
Turn o the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with the luminaire label information.
Make all electrical and grounded connections in accordance with the National Electric Code and any applicable local code requirements.
All wiring connections should be capped with UL approved wire connectors.
CAUTION: RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
Account for small parts and destroy packaging material, as these may be hazardous to children.
Ensure xtures are properly secured to T-bar grid and/or ceiling using wire or aircraft cable capable of supporting 100lbs minimum.
CAUTION: RISK OF FIRE
Keep combustible and other materials that can burn away from luminaire and lamp/lens.
MIN 90°C SUPPLY CONDUCTORS
What’s In The Box
One (1) T6CS
LED Troer
Tools Needed
This LED Troer requires very few tools for installation.
A drill or a screwdriver and a pair of wirecutter.
Installation
1
2
Preparation
Shut o power to desired circuit before any work.
Identify and prepare location for installation.
Carefully unpack the xture from its packaging and
inspect product for defects due to shipping.
Bend the four mounting/grid-tie clips up and out from
the xture.
Mounting
Place xture into t-grid ceiling.
Secure safety cable through hole in grid-tie clips per
local seismic codes.
Safety cable hole