8 Troubleshooting
Fault Cause Remedy
‡ Motor does not start > Fuse of the mains socket has
blown
• Connect mains fuse
> Overload protection switch
has tripped
• Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk-Alto service
department
> Motor is faulty • Have motor changed by
Nilfisk-Alto Service
‡
The acoustic warning
sounds. (Reduced suction
power)
> Hose diameter does not
correspond with switch
position
• Set correct switch position for
hose diameter
> Clogged suction hose/nozzle • Clean suction hose/nozzle
> Tank, disposal bag or filter
bag is full
• See "Emptying tank" or
"Replacing disposal bag, filter
bag" sections
> Filter element is clogged • See section „Cleaning filter
element“ and „Replacing filter
element“
> Seal between tank and upper
section of vacuum cleaner is
faulty or missing
• Replace seal
> Cleaning mechanism is
defective
• Contact Nilfisk-Alto Service
‡
No suction power during
wet cleaning
> Tank is full • Switch off the cleaner. Empty
the tank
‡
Voltage fluctuations > Impedance of power supply is
too high
• Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over
7% should not occur if the
impedance at the transfer point
is 0.15