Maintenance, cleaning and
repair
During the following work, ensure that dust is not unnecessarily
spread around. Wear a P2 breathing mask.
Only carry out maintenance work described in the operating instruc-
tions.
Always pull out the mains plug before cleaning and maintenance of
the vacuum cleaner.
During maintenance and cleaning, handle the vacuum cleaner in
such a manner that there is no danger for maintenance staff or other
persons.
In the maintenance area
1. Use filtered compulsory ventilation
2. Wear protective clothing
3. Clean the maintenance are so that no harmful substances get
into the surroundings.
Before removing the vacuum cleaner from the area contaminated
with harmful substances:
1. Clean the outside of the vacuum cleaner, wipe it clean or pack
the vacuum cleaner in well sealed packaging
2. and avoid spreading deposited harmful dust.
During maintenance and repair work all contaminated parts that
could not be cleaned satisfactorily must be:
1. packed in well sealed bags
2. disposed of in a manner that complies with valid regulations for
such waste removal.
A dust test must be performed at least once every year by Nilfisk-Alto
service or a trained person. This test includes, for example, whether
there is damage to the filter, the vacuum cleaner is sealed to the air
and the control equipment works properly.
Extension lead
1. As an extension lead, only use the version specified by the man-
ufacturer or one of a higher quality. See operating instructions.
2. When using an extension lead, check the minimum cross-sec-
tions of the cable:
Cable length Cross section
< 16 A < 25 A
up to 20 m 1.5 mm
2
2.5 mm
2
20 to 50 m 2.5 mm
2
4.0 mm
2
Electrical connection
1. It is recommended that the vacuum cleaner should be connected
via a residual current circuit breaker.
2. When picking up flammable dust in zone 22, extension lines,
couplings and adapters must not be used.
3. Arrange the electrical parts (sockets, plugs and couplings) and
lay down the extension lead so that the protection class is main-
tained.
4. Connectors and couplings of power supply cords and extension
leads must be watertight.