User Manual

12
TECHNICAL SPECIFICATIONS
Battery Banks
Amps/Bank
Total Amps
Input Voltage AC
Working Voltage AC
Nominal Voltage
Efciency
Charging Voltage
Back Current Drain
Ripple
Charger Type
Type of Batteries
Battery Chemistries
Battery Capacity
Housing Protection
Cooling
Output Leads (Length)
AC Cord (Length)
Dimensions (L x W x H)
Weight
GEN1
1
10A
10A
110-120VAC, 50-60Hz
70-130 VAC, 50-60Hz
12VDC
~90%
14.4V
<5mA
<2%
8 Step, Fully Automatic, Switch-Mode
12V Lead-Acid
Wet, Gel, MF & AGM
25-230Ah; Maintains All Battery Sizes
IP68
Natural Convection
6.3 Feet
6.0 Feet
7”x6”x3.3”
6.4lbs
GEN2
2
10A
20A
12VDCx2
8.5”x6.5”x3.3”
8.7lbs
GEN3
3
10A
30A
12VDCx3
11.5”x8.5”x3.25”
14.5lbs
GEN4
4
10A
40A
12VDCx4
15.6lbs
WICKED SMART TIP
BATTERY TESTING AND DIAGNOSTICS. The battery
charger will not begin delivering any current to the battery(s)
until the battery charger detects a ‘stable’ battery. A ‘stable’
battery means the eyelet terminal connectors are connected
to the battery with the correct polarity (POSITIVE-TO-
POSITIVE, NEGATIVE-TO-NEGATIVE) and have a tight,
clean connection to the battery being charged. If the battery
is not stable for at least three (3) seconds, the battery charger
will not begin charging the battery and the battery charger
will go into an ERROR condition. If the battery is connected
in reverse polarity, it is considered an ‘unstable’ battery and
the ERROR LED will illuminate until the ERROR is cleared by
reversing the eyelet terminal connectors.
Excluding Cords