Instructions

Charging Steps.
Step 1 & 2: Analyze & Diagnose
Checks the battery’s initial condition, including voltage,
state-of-charge and health, to determine if the battery is
stable before charging.
Step 3: Recovery
Initializes the Recovery desulfation process (if needed)
for deeply discharged or sulfated batteries by pulsing
small amounts of current.
Step 4: Initialize
Starts the charging process with a gentle (soft) charge.
Step 5: Bulk
Begins the Bulk charging process based on the
condition of the battery and returns 80% of the battery’s
capacity.
Step 6: Absorption
Brings the charge level to 90% by delivering small
amounts of current to provide a safe, efcient charge.
This limits battery gassing and is essential to prolonging
battery life.
Step 7: Optimization
Finalizes the charging process and brings the battery
to maximum capacity. In this step, the charger utilizes
multi-layered charging proles to fully recapture capacity
and optimize the specic gravity of the battery for
increased run time and performance. The charger will
switch to Maintenance if the battery tells the charger that
more current is needed.
1 2 3 4 5 6 7 8
Analyze
Step
Voltage (V)
Current (A)
Initialize
Diagnose
Bulk
Optimization
Recovery
Absorption
Maintenance