09/12 Rev. B 143573
33
Parameter
Description
Default
(BCF...)
Default
(BC...)
min
MAX
CONFIGURATION
C01
Door input (0 de-activated; 1 activated)
1
1
0
1
C02
Door open polarity
0
0
0
1
C03
Door open alarm delay
2 min
2 min
0 min
60 min
C04
Activates buzzer (0 de-activated; 1 activated)
1
1
0
1
C05
Buzzer duration at the end of quick cooling cycle
10 sec
10 sec
0
600 sec
C06
Temperature difference in the first phase of needle insertion
test (0 = test excluded)
13°F
45°F
0
140°F
C07
Duration of the second phase of needle insertion test (0=test
excluded)
56 sec
56 sec
0
600 sec
C08
Activates condenser probe
0 = no probe
1 = probe
1
1
0
1
C09
Compressor stop delay due to door opening
30 sec
30 sec
0 sec
60 sec
C10
Control pressure alarm detection time
5 sec
5 sec
0 sec
60 sec
C11
High pressure digital input polarity
0
0
0
1
C12
Resistances starting Set Point
23°F
23°F
14°F
68°F
ADJUSTMENT
R01
Compressor start/stop hysteresis
5°F
38°F
0°F
36°F
R02
Min. interval between 2 compressor starting
2 min
2 min
0 min
30 min
R03
Compressor start delay from card activation
0 sec
0 sec
0 sec
300 sec
R04
Compressor Duty-Cycle time with faulty room probe in storing
10 min
10 min
0 min
90 min
R05
Compressor ON time faulty room in pos. storing
3 min
3 min
0 min
90 min
R06
Compressor ON time with faulty room in neg. storing
8 min
8 min
0 min
90 min
R07
Needle min. temperature for starting quick cooling
158°F
158°F
32°F
194°F
R08
Compressor block temperature
194°F
194°F
32°F
212°F
R09
Compressor Protection function activation time
24 hour
24 hour
0 hour
240 hour
R10
Pulse duration
2 sec
2 sec
1 sec
10 sec
R11
Pause between pulses
8 sec
4 sec
1 sec
10 sec
R12
Number of pulses
3
3
1
20
R13
Temperature at the end of the Cooling cycle
-13°F
-13°F
-58°F
50°F
FANS
F01
Evaporator fans activation hysteresis
4°F
36°F
0°F
36°F
F02
Condenser fans activation hysteresis
4°F
36°F
0°F
36°F
F03
Evaporator fans activation Set Point
41°F
41°F
-58°F
122°F
F04
Condenser fans activation Set Point
59°F
59°F
-58°F
122°F
F05
Evaporator fans during defrost
0 = fans OFF; 1 = fans ON
0
0
0
1
F06
Condenser fans during defrost
0 = fans OFF; 1 = fans ON
0
0
0
1
F07
Fans stop time after defrost
1 min
1 min
0 min
30 min
F08
Condenser fans stop delay
30 sec
30 sec
0 sec
300 sec
F09
Evaporator fans control during quick cooling:
0 = fans always ON
1 = fans thermostated by evaporator temperature
0
0
0
1
F10
Evaporator fans control during storing:
0 = fans in parallel with the compressor
1 = fans thermostated by evaporator temperature
0
0
0
1
F11
Evaporator fans block temperature
158°F
158°F
32°F
194°F
PRINT
PR1
Sampling time
10 min
10 min
1 min
60 min
VENTILATION SPEED (P.W.M.)
CF1
Evaporator fan min. speed
30
20
0
100
CF2
Evaporator fan min. speed selectable in a quick cooling cycle
50
50
0
100