09/12 Rev. B 143573
34
Parameter
Description
Default
(BCF...)
Default
(BC...)
min MAX
I.F.R.
B01
Room thermostating temperature in the first phase
-48°F
-13°F
-58°F
122°F
B02
Under surface T control start temperature
41°F 86°F -58°F 210°F
B03
First coefficient of the control relation
0 -2 -50 50
B04
Second coefficient of the control relation
0 16 -50 50
B05
Third coefficient of the control relation
-8 -8 -50 50
B06
Under surface T initial value determining the end of the first phase
30°F
34°F -58°F 210°F
B07
Phase two formula coefficient
99 10 0 99
B09
Under surface t min. value allowed during the third phase
32°F 30°F -58°F 210°F
B10
End of intelligent quick cooling core temperature
46°F 38°F -58°F 210°F
B11
Delay from the positive result of the needle test for starting the
procedure to determine the end of the first phase
60 sec
60 sec
0 sec
99 sec
B12
First phase temperature detection time
30 sec 30 sec 0 sec 99 sec
B13
First phase min. duration
6 min 6 min 0 min 99min
B16
Defrost on starting intell. QC cycle (0=no 1=yes)
0 0 0 1
B17
Inhibition temperature
194°F 176°F -58°F 210°F
B18
Room Set point in the event of automatic switch to time or
temperature mode
19°F
32°F
-58°F
210°F
B19
Max. duration possibile for intelligent QC process
999 min 150 min 1 min 999 min
B20
Under surface T safety value determining the end of the first
phase
30°F
38°F
-58°F
210°F
B21
First coefficient of the room thermostating curve (third phase)
10
-25 -90 99
B22
Second coefficient of the room thermostating curve (third
phase)
-50
-28
-90
99
B23
Storing activation at the end of intell. QC cycle
(0 = no; 1 = yes)
1
1
0
1
B24
Room thermostat Set-point in storing
36°F 36°F -130°F 194°F
B26
Core temperature limit for the timer start
999 0 0 999
B27
Adjuster of fans speed in the third phase
99 0 0 99
B28
Cold pulse adjuster
10 0 0 99
COMMUNICATION
ADD
Device Address
1
1
1
147
SC
Serial Control :
0 = not activated
1 = print
2 = ModBus
1
1
0
2
MB1
BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200
2 2 0 3
MB2
Parity: 0 = no parity; 1 = odd; 2 = even
2 2 0 2
TYPE OF CYCLE
G01
Positive QC cycles only :
0 = Positive and Negative
1 = Positive only
0
1
0
1
CHANGING PARAMETERS
Press menu/esc to select the desired menu
Service
Use the keys up and down to display
Esc
Press enter to confirm your choice.
Service
The display shows
Password 0
(only the 1st time)