Instruction Manual

24
© 2013 Nor-Lake, Inc 07/13 Rev. F 132617
Fig. 11
THRESHOLD ATTACHMENT
The threshold was attached at the factory to the lower portion of the door section and it is positioned
in such a manner that no adjustment is required. It must, however, be attached to the building floor
to complete the installation.
IMPORTANT! Make sure that the slam braces are securely fastened to the door section and to the
building floor before attaching the threshold to the building floor. Both edges of the threshold should
be attached with fasteners that are appropriate for the building floor and, since the floor surfaces
vary so greatly in composition, no fasteners are provided and should be obtained by others (Fig. 12).
IMPORTANT!
MAKE SURE THAT THE
DOOR/DOOR SECTION IS
PERFECTLY PLUMB BEFORE
ATTACHING THE SLAM
BRACES TO THE FLOOR.
W
ALK
-I
N
I
NSTALLATION
-D
OOR
/D
OOR
S
ECTION
APPLY SEALANT UNDER THRESHOLD
Apply Sealant Under Threshold
Note: Add sealant between
threshold and floor to seal.
Walk-in insTallaTion -dooR/dooR secTion
Fig. 12