Installation Guide

22
Step
Installation Procedure(ex. @Garage)
Necessary Tool
26
Extend the lower end of "Flex Sleeve" to the sleeve clamp connector of the upper
portion of equipment.
Then secure with "2×Fastening Screws", and apply "Aluminum tape" covering the
connecting part. Make sure that it is firmly fixed by pulling by hand.
Do not stretch the "Flex Sleeve" where the screws are secured, it will weaken the
point where the screws are attached to the "Flex Sleeve".
Phillips head
Screwdriver
󰴭Fastening Screws
󰴮Aluminum tape
Step-3
(Work where equipment is installed)
Pay attention not to get injured from the sharp edge of "Flex Sleeve"
WARNING
Point
Check and see if "Flex Sleeve" is firmly fixed.
7.Maintenance
The venting system must be examined periodically by a qualified service technician to check for any leaks
or corrosion.
Check and confirm that there is no tension to the flexible vent by hanging or suspending of anything.
When changing the water heater, change whole venting components to new ones.
Periodically check the following to ensure proper
operation of the water heater.
45°
45°
Sleeve Clamp
<EZTR40>
<EZTR50 75>
Connector
Point
Screw locations are within
these two degree.