Installation Guide

9
6.Installation
In the installation, some work will be done above the roof, extra care and fall protection may be required.
Take extra care and responsibility to do the installation as safely as possible.
2.Tools necessary for the installation
3.Installation Procedure
Follow the below motioned procedure and install correctly. Specially, be sure to check eachPointcarefully.
If not installed correctly, the water heater will not function properly.
WARNING
For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken including
without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
Installation in windy or wet conditions require additional precautions. Follow local safety regulations.
Maximum Vent lengths
Max. Straight Vent Length: 35'(10.5m). Note that the kit comes with approximately 25' of
venting. If you need more than 25 feet of Flex pipe contact Noritz America 1-866-766-7489.
Max. allowable 45 degree elbows(B-Vent) are 2 elbows.
 Not including "
Rigid 45 Elbow Set"
 No 90
elbows(B-Vent)
Only when the all conditions of
"
4. Before Installation (Check the condition of installation)
"
are
satisfied, proceed with the installation, following the below mentioned installation procedure.
Screwdriver
Cutting tool
Tape Measure
Marker
Phillips head
Flat head
Box wrench(5/16")
For cutting the flexible vent.
PVC Cutter
Box Cutter
etc.
Hand saws are not approved
for cutting.
For [EZTR50] EZ98DV(GQ-C2859WX-FF US)
[EZTR75] EZ111DV(GQ-C3259WX-FF US)
Follow the instruction in the Flex Vent 2" Conversion Kit
Installation Manual to install the Flex Vent 2" Conversion Kit.
Note : This manual illustrates installation for the NRC663-FSV.
Installation for other models may vary slightly.
Only use the parts provided in the package for construction.