Ventilation Hood User Manual

CERTIFIED TEST DATA
Air delivery and sound level ratings are certified by the
Home Ventilating Institute Division of AMCA, based on
testing performed by an independent third party testing
laboratory, in accordance with HVI standards. This NuTone
model is listed by Underwriters' Laboratories Inc. and
Certified by the Canadian Standards Association (CSA.)
STATIC PRESSURE
INCHES OF WATER
CFM
0.0
140 128 116 80 - - -
0.1 0.2 0.5 1.0 1.5 1.75
STATIC PRESSURE
INCHES OF WATER
CFM
0.0
282 270 254 223 137 37 5
0.1 0.2 0.5 1.0 1.5 1.75
STATIC PRESSURE
INCHES OF WATER
CFM
0.0
161 145 132 88 - - -
0.1 0.2 0.5 1.0 1.5 1.75
The air delivery of a ventilating system may be
determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals
4 feet equivalent duct length and an 8 inch diameter duct
elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent duct
length.
3. Locate the intersection of the fan performance curve and
the total equivalent duct length curves and draw a
vertical line down to the CFM scale and read the system
air performance.
(NOTE: 3
1
4
" x 10" duct equals 6 inch diameter duct.)
AIR PERFORMANCE CURVE-ILF120
4 In. Duct
AIR PERFORMANCE CURVE-ILF250
6 In. Duct
AIR PERFORMANCE CURVE-ILF130
5 In. Duct
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9