Datasheet

KMZ60 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2014. All rights reserved.
Product data sheet Rev. 2 — 7 February 2014 19 of 30
NXP Semiconductors
KMZ60
Angle sensor with integrated amplifier
12. ElectroStatic Discharge (ESD)
12.1 Human body model
The KMZ60 is protected against 4 kV, according to the human body model at 100 pF and
1.5 k. The test is according to AEC-Q100, REV-G, method 002.
12.2 Machine model
The KMZ60 is protected against 400 V, according to the machine model. The test is
according to AEC-Q100, REV-G, method 003.
12.3 Charged-device model
The KMZ60 is protected against 500 V of direct charge injection with the 4 pF verification
model, according to the charged-device model. The test is according to AEC-Q100,
REV-G, method 011.
12.4 Latch-up protection
The KMZ60 is latch-up protected against 110 mA at maximum ambient temperature.
The test is according to AEC-Q100, REV-G, method 004.
13. Application information
The MR sensor is designed for applications with a separate Electronic Control Unit (ECU)
containing an ADC with its references connected to the supply voltage. With the ADC
input resolution related to V
CC
in the same way as the MR sensor output voltage range
(ratiometric), the signal dependency on supply voltage changes is minimized.
13.1 Connection to ECU
Long connections on the PCB should be avoided due to the limited driving capability of
both amplifier outputs. Shielding of the signal lines is recommended. The load capacitors
and resistors should be matched for best angular accuracy.
Fig 15. Application diagram of KMZ60 with separate ECU on Printed-Circuit Board (PCB)
DDQ
5
/RH[W
5
/RH[W
&
/RH[W
&
/RH[W
5
/RH[W
&
/RH[W
&
/LH[W
&
EORFNH[W
3&%3&%ZLWK.0=DQGDGGLWLRQDOFRPSRQHQWV
7&&B(1
WR9
&&
RU*1'
),/7(5
(&8
$'&
.0=
32:(5'2:1B(1
97(03
*1'
*1'
*1'
9287
9287
9
&&
9
&
&
9
&&
),/7(5