CONVERSION TO NATURAL GAS
WARNING! To avoid the possibility of burns conversion should only be done when the fire pit
is completely cool. Ensure burner is turned off. Turn gas off at source and disconnect the
appliance before beginning conversion.
WARNING! Fire Glass may have sharp edges. Wear safety glasses and gloves when handling.
WARNING! We recommend that the conversion be performed by a licensed gas fitter, and all
connections must be leak tested prior to operating the appliance.
2
3
4
Your fire pit can be easily converted to Natural Gas
by following these steps:
1. Remove the Fire Glass from the burner
.
2. Remove the burner from
the enclosure. T
ake care not
to damage or
kink the Thermocouple
Wire
.
3. Disconnect the Stainless Steel Flex Connector
from the Orifi
c
e
using
(2) Wrenches
.
4.
Unscrew the
Propane Orifi
c
e
from the
inside
of the
burner as
illustrated.
5. Replace the
Propane Orifice with the Natural Gas Orifice supplied. Note:
The Air Shutter has been factory set and does not need to be adjusted.
6. Reconnect the Stainless Steel Flex Connector to the Orifice and tighten
using (2) Wrenches.
7. Place the burner back into the enclosure.
8. Fill out the Conversion Label included with your Conversion Kit and
apply it to the inside of the Control Panel Access Door.
A leak test must be performed according to the leak testing instructions
found in the manual.