User manual

DE
EN
FR
NL
ES
PT
IT
DA
NO
SV
FI
HU
PL
CS
SK
SL
HR
RO
BG
UK
RU
CN
13
OPERATION
WARNING
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
Only connect the pump to the power
supply when there are no persons in or
reaching into the water.
Before stepping into or reaching into the
water, switch off all units located in the
water.
Switching on the unit
Insert the power plug into the socket.
The pump is ready for operation.
The pump will start up as soon as the
level of the water reaches the switch-
on height.
Switching off the unit
Disconnect the power plug.
When the pump is switched off, resid-
ual water in the hose may flow back
and out of the pump intake.
NOTE
Do not use the unit for long-term opera-
tion. Otherwise this will impair the operat-
ing life of the unit accordingly.
NOTE
Rinse the pump with clean water after
use.
REMEDY OF FAULTS
Malfunction
Cause
Remedy
Pump does not start.
Power supply interrupted
Check the fuse and electri-
cal plug connections.
Pump switches off after a
short running period.
Overload protection has
switched the pump off due
to overheating.
Clean the intake and
pressure hose.
Allow the pump to cool
down.
The pump is running but is
not delivering, or the deliv-
ered quantity is insufficient
Pressure hose kinked
Route the pressure hose
without kinks
Check the outlet and
clean if necessary
Intake blocked
Clean the intake
Air in the pressure hose
Expel the air from the
pressure hose.
If applicable:
Non-return valve incorrectly
fitted in the pressure hose
or clogged
Correctly fit the non-re-
turn valve.
Clean the non-return
valve.
Impeller defective or worn
Contact OASE
The impeller may only
be replaced by the
OASE Service.