2.6.7 - Connection of the condensate drain line
Connect a drain pipe, of appropriate length, to the indoor unit condensate drain pipe, and block it with a strap.
Make it run inside the duct parallel to the system pipes, fastening it to the same using straps.

of the pipes and narrow the drain pipe.

If the drain pipe is fed into a sewage system, it is necessary to bend the pipe in

odours into the environment.



prevent counter-pressures such to compromise the operation, and the pipe itself
must never reach the level of the liquid deposited.
Check the correct run-off of the condensate liquid through the relative pipe by very

