HEM-7321-Z_C_M.book Page 1 Monday, June 16, 2014 12:09 PM Contents Thank you for purchasing the OMRON® BP785N Blood Pressure Monitor. Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
HEM-7321-Z_C_M.book Page 1 Monday, June 16, 2014 12:09 PM Important Safety Information Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure. The monitor is not intended to be a diagnostic device.
HEM-7321-Z_C_M.book Page 2 Monday, June 16, 2014 12:09 PM Important Safety Information Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. (General Usage) Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. Consult your physician before using the device for any of the following conditions: •If you have had a mastectomy.
HEM-7321-Z_C_M.book Page 3 Monday, June 16, 2014 12:09 PM Important Safety Information When handling the power cord, take care not to do the following: Do not damage. Do not break it. Do not tamper with it. Do not forcibly bend or pull. Do not twist. Do not bundle during use. Do not pinch. Do not place under heavy objects. Wipe the dust off from the power plug. Unplug monitor when not in use. Disconnect the power plug before cleaning. Use only an OMRON AC adapter designed for this device.
HEM-7321-Z_C_M.book Page 4 Monday, June 16, 2014 12:09 PM 1. Know Your Device Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page.
HEM-7321-Z_C_M.book Page 5 Monday, June 16, 2014 12:09 PM 1. Know Your Device 1.1 Display Symbols Irregular Heartbeat Symbol ( ) When the monitor detects an irregular rhythm two or more times during the Pulse measurement, the irregular heartbeat symbol will appear on the display with Blood pressure the measurement values.
HEM-7321-Z_C_M.book Page 6 Monday, June 16, 2014 12:09 PM 1. Know Your Device Blood Pressure Color Indicator If your Systolic Blood Pressure is 135 mmHg or above and/or the Diastolic Blood Pressure is 85 mmHg or above, the blood pressure color indicator will light in “orange” when the measurement result is displayed. If the results are within the standard range, the blood pressure color indicator will light in “green”.
HEM-7321-Z_C_M.book Page 7 Monday, June 16, 2014 12:09 PM 2. Preparation 2.1 Battery Installation 1. Remove the battery cover. 2. Insert 4 “AA” batteries as EN indicated in the battery compartment. 3. Replace the battery cover. Notes: • When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended. • The measurement values continue to be stored in memory even after the batteries are replaced.
HEM-7321-Z_C_M.book Page 8 Monday, June 16, 2014 12:09 PM 2. Preparation 2.2 Using the AC adapter IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - DANGER TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOLLOW THESE INSTRUCTIONS. The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position. NOTES: • Use only the authorized OMRON AC Adapter that came with this monitor. • We recommend you install the batteries even if the AC Adapter is used.
HEM-7321-Z_C_M.book Page 9 Monday, June 16, 2014 12:09 PM 2. Preparation 1. Insert the AC adapter plug into the AC adapter jack on the rear side of the monitor. 2. Plug the AC adapter into an EN electrical outlet. To disconnect the AC adapter, unplug the AC adapter from the electrical outlet first and then remove the AC adapter plug from the monitor.
HEM-7321-Z_C_M.book Page 10 Monday, June 16, 2014 12:09 PM 2. Preparation 2.3 Setting the TruReadTM Mode The TruReadTM Mode takes 3 consecutive measurements. The monitor will inflate, take a measurement, and deflate - 3 times, separated by a short interval between each measurement. The TruReadTM Mode is set “oFF” by default. 1. Select your USER ID (1 or 2). 2. Press the TM The TruRead button. symbol ( ) appears on the display. 1) Press “oFF”. 2) Press the button to confirm.
HEM-7321-Z_C_M.book Page 11 Monday, June 16, 2014 12:09 PM 2. Preparation Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page. 2.4 Setting the Date and Time Set the monitor to the correct date and time before taking a measurement for the first time. 1. Press the C Date/Time setting ( ) button. EN The year flashes on the T Date/Time display. 2. Push or button to change the year.
HEM-7321-Z_C_M.book Page 12 Monday, June 16, 2014 12:09 PM 3. Using the Device Open both the front and rear covers to read the following: The letter identifiers on the cover page correspond to those in the body of this page. 3.1 Applying the Arm Cuff Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. Do not place the arm cuff over thick clothes. 1. Insert L the air plug into A the air jack securely. 2. Apply the arm cuff to your left upper arm.
HEM-7321-Z_C_M.book Page 13 Monday, June 16, 2014 12:09 PM 3. Using the Device 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • • • • Sit on a chair with your feet flat on the floor. Sit upright with your back straight. --- c Sit with your back and arm being supported.
HEM-7321-Z_C_M.book Page 14 Monday, June 16, 2014 12:09 PM 3. Using the Device 3.3 Taking a Measurement Notes: • To stop the measurement, press the START/STOP button once to deflate the arm cuff. • Remain still and quiet while taking a measurement. The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2. Using the Single Mode 1. Select your USER ID (1 or 2). 2. Press the START/STOP button.
HEM-7321-Z_C_M.book Page 15 Monday, June 16, 2014 12:09 PM 3. Using the Device 3. Remove the arm cuff. 4. Press the START/STOP button to turn the monitor off. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes. Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the EN arteries to return to the condition prior to taking a measurement. Using the TruReadTM Mode 1. Select your USER ID (1 or 2). 2.
HEM-7321-Z_C_M.book Page 16 Monday, June 16, 2014 12:09 PM 3. Using the Device The first measurement is complete, waiting to start the next measurement. The interval will appear on the display. The second measurement is complete, waiting to start the next measurement. The interval will appear on the display. The third measurement is complete, the average for the 3 measurements appears on the display. 16 Press the button to display the individual measurement values.
HEM-7321-Z_C_M.book Page 17 Monday, June 16, 2014 12:09 PM 3. Using the Device Using the Guest Mode The monitor stores measurement values for 2 users in the memory. The guest mode can be used to take a single measurement for another user. No measurement values are stored in the memory, and the TruReadTM mode is not available when the guest mode is selected. 1. Press and hold the START/STOP EN button for more than 3 seconds. The USER ID symbol and the Date/Time display will disappear. 2.
HEM-7321-Z_C_M.book Page 18 Monday, June 16, 2014 12:09 PM 3. Using the Device 3.4 Using the Memory Function The monitor automatically stores the results up to 100 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes. Notes: • If there are only 2 measurement values in the memory for that period, the average will be based on these 2 values.
HEM-7321-Z_C_M.book Page 19 Monday, June 16, 2014 12:09 PM 3. Using the Device 3. Press the or button to view the values stored in the memory. : To view the older values : To view the more recent values Note: The value with the TruReadTM symbol is the average for the consecutive 3 measurements. To display the individual measurement values, press the EN button while the average is displayed. To View the Average Value 1. Select your USER ID (1 or 2). 2.
HEM-7321-Z_C_M.book Page 20 Monday, June 16, 2014 12:09 PM 3. Using the Device To Delete All the Values Stored in Memory The values stored in the memory are deleted by USER ID. 1. Select your USER ID (1 or 2). 2. Press the Memory button, while the memory symbol ( appears. 3. While holding the button down, press the START/STOP button for more than 3 seconds. Note: You cannot partially delete the values stored in the memory. All values for the user you select will be deleted.
HEM-7321-Z_C_M.book Page 21 Monday, June 16, 2014 12:09 PM 4. Error Messages and Troubleshooting 4.1 Error Messages Display Cause Solution Irregular heartbeats are detected. Remove the arm cuff. Wait 2-3 minutes and then take another measurement. Repeat the steps in section 3.3. If this error continues to appear, contact your physician. Movement during measurement. Carefully read and repeat the steps in section 3.3. The batteries are low.
HEM-7321-Z_C_M.book Page 22 Monday, June 16, 2014 12:09 PM 4. Error Messages and Troubleshooting Display Cause Air plug disconnected. Insert the air plug securely. Refer to section 3.1. Arm cuff is applied too loosely. Apply the arm cuff tighter. Refer to section 3.1. Air is leaking from the arm cuff. Replace the arm cuff with a new one. Refer to section 5.3. Movement during measurement and the arm cuff has not been inflated sufficiently. 22 Solution Repeat measurement.
HEM-7321-Z_C_M.book Page 23 Monday, June 16, 2014 12:09 PM 4. Error Messages and Troubleshooting 4.2 Troubleshooting Problem Cause and Solution No power. No display appears on the monitor. Replace all batteries with new ones. Check the battery installation for proper placement of the battery polarities. Refer to section 2.1. Measurement values appear too high or too low. Blood pressure varies constantly.
HEM-7321-Z_C_M.book Page 24 Monday, June 16, 2014 12:09 PM 5. Maintenance and Storage 5.1 Maintenance To protect your device from damage, please observe the following: • • • • Store the device and the components in a clean, safe location. Do not use any abrasive or volatile cleaners. Do not wash the device and any components or immerse them in water. Do not use gasoline, thinners or similar solvents to clean the device.
HEM-7321-Z_C_M.book Page 25 Monday, June 16, 2014 12:09 PM 5. Maintenance and Storage 5.2 Storage 1. Unplug the air plug from the air jack. 2. Gently fold the air tube into the EN arm cuff. Note: Do not bend or crease the air tube excessively. Do not store the device in the following situations: • If the device is wet. • Locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapors such as bleach.
HEM-7321-Z_C_M.book Page 26 Monday, June 16, 2014 12:09 PM 5. Maintenance and Storage 5.
HEM-7321-Z_C_M.book Page 27 Monday, June 16, 2014 12:09 PM 6. Specifications Model Display Measurement range Accuracy Inflation Deflation Measurement method IP classification Power source Battery life Operating temperature / humidity Storage temperature / humidity / air pressure Weight Dimensions Cuff circumference Memory Contents Applied part Protection against electric shock BP785N HEM-7321-Z LCD digital display Pressure: 0 to 299 mmHg Pulse: 40 to 180 beats / min.
HEM-7321-Z_C_M.book Page 28 Monday, June 16, 2014 12:09 PM 7. FCC Statement FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
HEM-7321-Z_C_M.book Page 29 Monday, June 16, 2014 12:09 PM 8. Limited Warranty Your BP785N Automatic Blood Pressure Monitor, excluding the arm cuff, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor.
HEM-7321-Z_C_M.book Page 30 Monday, June 16, 2014 12:09 PM 9. Guidance and Manufacturer’s Declaration OMRON Automatic Blood Pressure Monitor Information for accompanying documents in the scope of IEC60601-1-2:2007 Model: BP785N including AC-adapter Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices.
HEM-7321-Z_C_M.book Page 31 Monday, June 16, 2014 12:09 PM 9. Guidance and Manufacturer’s Declaration Guidance and manufacturer’s declaration - electromagnetic immunity OMRON BP785N including AC-adapter is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP785N including AC-adapter should assure that it is used in such environment.
HEM-7321-Z_C_M.book Page 32 Monday, June 16, 2014 12:09 PM 9. Guidance and Manufacturer’s Declaration Guidance and manufacturer’s declaration - electromagnetic immunity OMRON BP785N including AC-adapter is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP785N including AC-adapter should assure that it is used in such environment.
HEM-7321-Z_C_M.book Page 33 Monday, June 16, 2014 12:09 PM 9. Guidance and Manufacturer’s Declaration Recommended separation distance between portable and mobile RF communications equipment and the OMRON BP785N including AC-adapter OMRON BP785N including AC-adapter is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
HEM-7321-Z_C_M.
HEM-7321-Z_C_M.
HEM-7321-Z_C_M.
HEM-7321-Z_C_M.book Page vii Monday, June 16, 2014 12:09 PM Manufactured for : OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN Distributed by : OMRON HEALTHCARE, INC. 1925 West Field Court Lake Forest, IL 60045 U.S.A. www.omronhealthcare.com © 2014 OMRON HEALTHCARE, INC. Made in Vietnam Fabricado para : OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPÓN Distribuido por : OMRON HEALTHCARE, INC. 1925 West Field Court Lake Forest, IL 60045 U.S.