Datasheet

Table Of Contents
24
D6F-AB71 MEMS Flow Sensor
Characteristics/Performance
Note: 1. Volumetric flow rate at 0°C, 101.3 kPa.
Note: 2. Dry gas (must not contain large particles, e.g., dust, oil, or mist.)
Note: 3. Reference (typical)
Note: 4. With no condensation or icing.
Dimensions (Unit: mm)
Model D6F-30AB71-000 D6F-70AB71-000
Flow Range (See note 1.) 0 to 30 L/min 0 to 70 L/min
Calibration Gas (See note 2.) Air
Flow Port Type Quick joint P14
Electrical Connection Three-pin connector
Power Supply 10.8 to 26.4 VDC
Current Consumption 15 mA max. with no load and Vcc of 12 to 24 VDC, GND = 0 VDC, 25°C
Output Voltage 1 to 5 VDC (non-linear output, load resistance of 10 kΩ min.)
Accuracy ±3%F.S. (25°C characteristic)
Repeatability (See note 3.) ±0.3%F.S.
Output Voltage (Max.) 5.7 VDC (Load resistance: 10 kΩ)
Output Voltage (Min.) 0 VDC (Load resistance: 10 kΩ)
Rated Power Supply Voltage 26.4 VDC
Rated Output Voltage 6 VDC
Case PPS
Degree of Protection IEC IP40 (Excluding tubing sections.)
Withstand Pressure 100 kPa
Pressure Drop (See note 3.) 0.88 kPa 3.49 kPa
Operating Temperature (See note 4.) –10 to +60°C
Operating Humidity (See note 4.) 35 to 85%RH
Storage Temperature (See note 4.) –30 to +80°C
Storage Humidity (See note 4.) 35 to 85%RH
Temperature Characteristics ±3%F.S. for 25°C characteristic at an ambient temperature of –10 to +60°C
Insulation Resistance Between sensor outer cover and lead terminals: 20 MΩ min. (at 500 VDC)
Dielectric Strength Between sensor outer cover and lead terminals: 500 VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA max.)
Weight 75 g
Please visit our CAD Data website, which is noted on the last page.
CAD Data
C0.3
C0.5
R0.4
R0.4
C0.1
Y
XX
20.5
25.8
30.9
2-2.6 dia Depth 6.5 (See
note 2.)
Lot No. Display
If using a Rc3/8 converter joint, the following is recommended.
REGAL JOINT CO., LTD http://www.rgl.co.jp/
Converter male joint (Rc3/8-Quick male joint): Adapter Rc3/8-QJM14
O ring: O ring P14 fluororubber (material)
9 max.
1.6 max
2.5
±
0.05
2 min. 2 min.
2.5
+0.25
-0
CROSS X-X Description Y
17.85
±
0.05
dia.
26 dia.
22 dia.
max.
(60.6)
(64.5)
(66.6)
84.6
(6)
(3.7)
(33.4)
30
32
30
A
A
B
See
note 1.
Note 1. The flow path inlet and outlet ports conform to P14-type female
quick-connect joints.
(The tube inlet and outlet ports have the same shape.)
* P14 is the number of an O-ring specified in JIS B 2401.
* The O-ring groove in the male joint must conform to P14 in JIS B 2406.
* Please obtain a male joint separately.
Note 2. To mount the Sensor with 2.6-dia. holes, use P-type self-tapping screws with
a nominal diameter of 3 mm and tighten them to a torque of 1.2 N·m max.
The screw threads must engage for 5.5 mm min.
Note 3: Use the following connectors to connect to the Sensor.
Connector : GHR-04V-S (JST)
Terminals : SSHL-002T-P0.2 (JST)
Wires : AWG26 to AWG30
Circuit numbers : 1. Vcc, 2. SDA, 3. SCL, and 4. GND.
C0.5 (circumference)
C0.5 (circumference)
R2 (circumference)
6
3
±0.15
30
°
26 dia.
0.9
22 dia.
18 dia.
+0.1
-0.05
CROSS A-A
14 dia.
+0
-0.05
CAD Data
MEMS Flow Sensors
D6F-30AB71-000
D6F-70AB71-000
Recommended Quick joint male P14 type