D6F-P MEMS Flow Sensor
Characteristics/Performance
Note: 1. Volumetric flow rate at 0°C, 101.3 kPa.
Note: 2. Dry gas. (must not contain large particles, e.g., dust, oil, or mist.)
Note: 3. Reference (typical)
Note: 4. With no condensation or icing.
Tubing
You can measure large flows by mounting the Sensor on a bypass.
Model D6F-P0001A1 D6F-P0010A1 D6F-P0010A2 D6F-P0010AM2
Flow Range (See note 1.) 0 to 0.1 L/min 0 to 1 L/min
Calibration Gas (See note 2.) Air
Flow Port Type
Bamboo joint
Maximum outside diameter: 4.9 mm, minimum outside diameter: 4.0 mm
Manifold
Electrical Connection Lead terminals Three-pin connector
Power Supply 4.75 to 5.25 VDC
Current Consumption 15 mA max. with no load and a Vcc of 5.0 V
Output Voltage 0.5 to 2.5 VDC (Load resistance: 10 kΩ)
Accuracy ±5% FS (25°C characteristic)
Repeatability (See note 3.) ±1.0% FS ±0.4% FS
Output Voltage (Max.) 3.1 VDC (Load resistance: 10 kΩ)
Output Voltage (Min.) 0 VDC (Load resistance: 10 kΩ)
Rated Power Supply Voltage 10 VDC
Rated Output Voltage 4 VDC
Case PBT
Degree of Protection IEC IP40 (Excluding tubing sections.)
Withstand Pressure (See note 3.) 50 kPa
Pressure Drop (See note 3.) 0.005 kPa 0.19 kPa 0.67 kPa
Operating Temperature (See note 4.) 10 to +60°C
Operating Humidity (See note 4.) 35% to 85%
Storage Temperature (See note 4.) 40 to +80°C
Storage Humidity (See note 4.) 35% to 85%
Temperature Characteristics ±5% FS for 25°C characteristic at an ambient temperature of -10 to +60°C
Insulation Resistance Between sensor outer cover and lead terminals: 20 MΩ min. (at 500 VDC)
Dielectric Strength Between sensor outer cover and lead terminals: 500 VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA max.)
Weight 8.5 g 8.0 g
P1
Resistance to flow
Mounting Direction
Bamboo joint Sensor Manifold-type Sensor
D6F-P
Flow Sensor