Datasheet

Table Of Contents
34
D6F-W
MEMS Flow Sensor
A Compact Sensor That Uses
OMRON’s Unique Flow Path Structure
for High-Performance Flow Velocity*
Measurement.
Anti-dust performance enhanced by OMRON’s unique three-dimensional
flow path structure.
High accuracy of ±5% FS.
* The flow velocity is the value calculated from the mass flow rate in OMRON's specified wind tunnel.
It does not indicate the flow velocity determined by the Measurement Law of JAPAN.
Ordering Information
MEMS Flow Sensor
Accessory (Sold separately)
Note: Refer to Accessories for the D6F Series on page 38.
Connections
Output Voltage Characteristics
D6F-W01A1
D6F-W04A1
The flow velocity is the value calculated from the mass flow rate in OMRON’s specified
48-mm-dia. wind tunnel. It does not indicate the flow velocity determined by the Mea-
surement Law of Japan. The wind tunnel conditions are shown in
Figure 1
, below.
Measurement conditions: Power supply voltage of 12 VDC, ambient tempera-
ture of 25°C, and ambient humidity of 35% to 75%.
D6F-W10A1
The flow velocity is the value calculated from the mass flow rate in OMRON’s specified
155-mm-dia. wind tunnel. It does not indicate the flow velocity determined by the Mea-
surement Law of Japan. The wind tunnel conditions are shown in
Figure 2
, below.
Measurement conditions: Power supply voltage of 12 VDC and ambient temper-
ature of 25°C
RoHS Compliant
Refer to the Common Precautions for the D6F Series on page 39.
Applicable fluid Flow rate range Model
Air
0 to 1 m/s D6F-W01A1
0 to 4 m/s D6F-W04A1
0 to 10 m/s D6F-W10A1
Type Model
Cable
D6F-W CABLE
D6F-W CABLE-L
Enlarged View
2. Vout.
3. GND.
1. Vcc.
Pin No. 1: Vcc
2: Vout
3: GND
Connector S3B-ZR-SM2-TF
(made by J.S.T. Mfg. Co.)
D6F-W01A1
D6F-W04A1
D6F-W10A1
Use the following connectors from
J.S.T. Mfg. Co. Ltd. to connect the D6F:
Housing: ZHR-3
Contacts: SZH-002T-P0.5
Wires: AWG28 to AWG26
Or
Contacts: SZH-003T-P0.5
Wires: AWG32 to AWG28
Flow velocity
m/s
0 0.25 0.50 0.75 1.00
Output voltage V
1.00±0.2 1.35±0.2 2.01±0.2 3.27±0.2 5.00±0.2
Flow velocity
m/s
0 1.0 2.0 3.0 4.0
Output voltage V
1.00±0.2 1.58±0.2 2.88±0.2 4.11±0.2 5.00±0.2
Flow velocity
m/s
0 2.0 4.0 6.0 8.0 10.0
Output voltage V
1.00
±
0.24 1.94
±
0.24 3.23
±
0.24 4.25
±
0.24 4.73
±
0.24 5.00
±
0.24
6.0
5.0
4.0
3.0
2.0
1.0
0.250.00 1.000.750.50
0.0
Output voltage (V)
Flow velocity (m/s)
1.00.0 4.03.02.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Output voltage (V)
Flow velocity (m/s)
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0246810
Output voltage (V)
Flow velocity (m/s)
D6F-W01A1 D6F-W04A1
D6F-W10A1
48 dia.
60 20.8
Air volume sensor
Flow velocity measurement
position
Figure 1: Wind Tunnel
100
10
18
155 dia.
Honeycomb flow grate
Air volume sensor
Flow velocity measurement position
Figure 2: Wind Tunnel