Datasheet

Table Of Contents
35
D6F-W MEMS Flow Sensor
Characteristics/Performance
Note: 1. Volumetric flow rate at 25°C, 101.3 kPa.
Note: 2. Dry gas. (must not contain large particles, e.g., dust, oil, or mist.)
Note: 3. Reference (typical)
Note: 4. With no condensation or icing.
Dimensions (Unit: mm)
Model D6F-W01A1 D6F-W04A1 D6F-W10A1
Flow Range (See note 1.) 0 to 1 m/s 0 to 4 m/s 0 to 10 m/s
Calibration Gas (See note 2.) Air
Electrical Connection Three-pin connector
Power Supply 10.8 to 26.4 VDC
Current Consumption 15 mA max. with no load, with a Vcc of 12 to 24 VDC, and at 25°C
Output Voltage 1 to 5 VDC (non-linear output, load resistance of 10 kΩ)
Accuracy ±5% FS (25°C characteristic) ±6% FS (25°C characteristic)
Repeatability (See note 3.) ±0.4% FS
Output Voltage (Max.) 5.7 VDC (Load resistance: 10 kΩ)
Output Voltage (Min.) 0 VDC (Load resistance: 10 kΩ)
Rated Power Supply Voltage 26.4 VDC
Rated Output Voltage 6 VDC
Case PPS
Degree of Protection IEC IP40 (except for flow inlet and outlet)
Operating Temperature (See note 4.) 10 to 60°C
Operating Humidity (See note 4.) 35% to 85%
Storage Temperature (See note 4.) 40 to 80°C
Storage Humidity (See note 4.) 35% to 85%
Temperature Characteristics ±5% FS for 25°C characteristic at an ambient temperature of 10 to 60°C
Insulation Resistance Between sensor outer cover and lead terminals: 20 MΩ min. (at 500 VDC)
Dielectric Strength Between sensor outer cover and lead terminals: 500 VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA max.)
Weight 6.3 g
Please visit our CAD Data website, which is noted on the last page.
CAD Data
MADE IN JAPAN
4.2
±0.2
3.2
±0.2
Two, R: 1.6
30.5
±0.2
19.5
2 dia., Depth: 2.5
3.2 ±0.2 dia.
4
5
Flow inlet
1.2
2.6
9
20
8
R4
R4
8
24 39
7
Flow outlet
Flow outlet
1.2
2.6
Two, M3 screws
Lot number label
30.5
±0.05
5
CAD Data
Mounting Hole Dimensions
MEMS Flow Sensors
D6F-W01A1
D6F-W04A1
D6F-W10A1