Common Precautions for the D6F Series
D6F-A7/-L7/-N7/-A7D/-AB71/-AB71D
(1)
Use male quick couplings for the piping, and secure them
with the applicable quick fasteners.
(2)
Do not apply excessive force to the adapter section when
connecting the pipes. If strong force is applied to the con-
nected pipes, or if strong force is applied directly to the
adapter section while holding the Sensor, it may damage
the Sensor or cause leakage.
Note. There is a possibility that leak damage or faulty of the body occurs when
static load of more than 40 N is applied to 300 mm from the center of
product as fulcrum point.
D6F-P0001A1/-P0010A1/-P0010A2
(1)
Depending on the ambient environment and installation
location, dust, dirt, and other foreign matter may come in
inside the Sensor and block a part or all of the flow path or
accumulate on internal components. This may result in the
Sensor not being able to perform to the specifications given
above. Always perform a pre-evaluation on your actual
equipment and be aware of the possible problems that may
occur before you use the Sensor with the actual equipment.
(2)
Attach all tubes so that the fluid flows only in the direction
from the positive side (+) to the negative side (-).
Refer to the figure on page 26 for the installation direction.
(3)
For PCB-mounting Sensors, perform terminal soldering only
after the Sensor is secured into place on the PCB.
Use a soldering iron for 5 s at 350°C with a pressure of 100
gf max. (This applies only to PCB-mounting Sensors.)
(4)
Use M2.6 panhead screws or equivalent tapping screws to
mount the Sensor, and tighten the screws to a maximum
torque of 0.59 N•m.
D6F-P0010AM2
(1)
Depending on the ambient environment and installation
location, dust, dirt, and other foreign matter may come in
inside the Sensor and block a part or all of the flow path or
accumulate on internal components. This may result in the
Sensor not being able to perform to the specifications given
above. Always perform a pre-evaluation on your actual
equipment and be aware of the possible problems that may
occur before you use the Sensor with the actual equipment.
(2)
Attach all tubes so that the fluid flows only in the direction
from the positive side (+) to the negative side (-). Install the
Sensor with the manifold facing downward. Refer to the fig-
ure on page 26 for the installation direction.
(3)
Use M3 panhead screws or equivalent tapping screws to
mount the Sensor, and tighten the screws to a maximum
torque of 0.59 N•m.
(4)
Install O-rings to seal the fluid inlet and outlet points. The
recommended O-ring is JIS B 2401, nominal number P4.
D6F-PHAD1/-PHAD2/-PHAD3/-PHAD4
(1)
Depending on the ambient environment and installation
location, dust, dirt, and other foreign matter may come in
inside the Sensor and block a part or all of the flow path or
accumulate on internal components. This may result in the
Sensor not being able to perform to the specifications given
above. Always perform a pre-evaluation on your actual
equipment and be aware of the possible problems that may
occur before you use the Sensor with the actual equipment.
(2)
Attach all tubes so that the fluid flows only in the direction
from the high pressure side (+) to the low pressure side (-).
(3)
Use M1.8 panhead screws or equivalent tapping screws to
mount the Sensor, and tighten the screws to a maximum
torque of 0.36 N•m.
(4)
The sensor output is affected with the length of a tube. The
error is less than 1% with a tube (ID:4mm) length up to 800mm.
(5)
Connection (D6F-PHAD1/-PHAD3)
•Wire with the correct terminal names and polarities. Incor-
rect wiring will cause failure of internal components.
•Do not use flow soldering.
•Please solder after fixed on the circuit board by screw.
•Use a soldering iron:
Soldering condition Pressure Max.100gf
Temperature 350 degree C
Time Max. 5s
Quick fastener
Male quick couplings
9 max.
1.6 max.
2.5
±
0.05
2 min. 2 min.
C0.3
C0.5
BADC
R0.4
R0.4
C0.1
2.5
+0.25
-0
10 dia.
+0
-0.05
14 dia.
+0
-0.05
CROSS X-X Description Y
X
Y
X
12.85
±
0.05
dia.
20 dia.
17 dia. max.
17.85
±
0.05
dia.
26 dia.
22 dia. max.
Symbol
A
B
C
D
P10 model P14 model
Installation Example
Use male, P10-type quick-connect joints for the D6F-A7/-L7/-
N7/-A7D and P14-type quick-connect joints for the D6F-AB71/-
AB71D.
Applicable male quick coupling dimensions (Unit: mm)
O-ring
M3 panhead screw or a tappin
screw with the same diameter
Installation Example