Datasheet

MC7800, MC7800A, LM340, LM340A Series, NCV7805
http://onsemi.com
10
ELECTRICAL CHARACTERISTICS (continued) (V
in
= 23 V, I
O
= 1.0 A, T
J
= T
low
to T
high
[Note 1], unless
otherwise noted.)
MC7815AB/MC7815AC/LM340AT–15
Characteristic Symbol Min Typ Max Unit
Ripple Rejection RR 60 80 dB
18.5 Vdc V
in
28.5 Vdc, f = 120 Hz, I
O
= 500 mA
Dropout Voltage (I
O
= 1.0 A, T
J
= 25°C) V
I
– V
O
2.0 Vdc
Output Noise Voltage (T
A
= 25°C) V
n
10 µV/V
O
10 Hz f 100 kHz
Output Resistance f = 1.0 kHz r
O
1.2 m
Short Circuit Current Limit (T
A
= 25°C) I
SC
0.2 A
V
in
= 35 Vdc
Peak Output Current (T
J
= 25°C) I
max
2.2 A
Average Temperature Coefficient of Output Voltage TCV
O
–1.0 mV/°C
ELECTRICAL CHARACTERISTICS (V
in
= 27 V, I
O
= 500 mA, T
J
= T
low
to T
high
[Note 1], unless otherwise noted.)
MC7818B MC7818C
Characteristic Symbol Min Typ Max Min Typ Max Unit
Output Voltage (T
J
= 25°C) V
O
17.3 18 18.7 17.3 18 18.7 Vdc
Output Voltage (5.0 mA I
O
1.0 A, P
D
15 W) V
O
Vdc
21 Vdc V
in
33 Vdc 17.1 18 18.9
22 Vdc V
in
33 Vdc 17.1 18 18.9
Line Regulation, (Note 2) Reg
line
mV
21 Vdc V
in
33 Vdc 9.5 360 9.5 50
24 Vdc V
in
30 Vdc 3.2 180 3.2 25
Load Regulation, (Note 2) Reg
load
2.0 360 2.0 55 mV
5.0 mA I
O
1.5 A
Quiescent Current I
B
3.5 8.0 3.5 6.5 mA
Quiescent Current Change I
B
mA
21 Vdc V
in
33 Vdc 1.0
5.0 mA I
O
1.0 A 0.5 0.5
Ripple Rejection RR 57 53 57 dB
22 Vdc V
in
33 Vdc, f = 120 Hz
Dropout Voltage (I
O
= 1.0 A, T
J
= 25°C) V
iI
– V
O
2.0 2.0 Vdc
Output Noise Voltage (T
A
= 25°C) V
n
10 10 µV/V
O
10 Hz f 100 kHz
Output Resistance f = 1.0 kHz r
O
1.3 1.3 m
Short Circuit Current Limit (T
A
= 25°C) I
SC
0.2 0.2 A
V
in
= 35 Vdc
Peak Output Current (T
J
= 25°C) I
max
2.2 2.2 A
Average Temperature Coefficient of Output Voltage TCV
O
–1.5 –1.5 mV/°C
1. T
low
=0°C for MC78XXAC, C, LM340AT–XX, LM340T–XX T
high
= +125°C for MC78XXAC, C, LM340AT–XX, LM340T–XX, NCV7805
= 40°C for MC78XXB, MC78XXAB, NCV7805
2. Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.