Datasheet

MC7800, MC7800A, LM340, LM340A Series, NCV7805
http://onsemi.com
5
ELECTRICAL CHARACTERISTICS (V
in
= 11 V, I
O
= 1.0 A, T
J
= T
low
to T
high
[Note 1], unless otherwise noted.)
MC7806AC
Characteristic Symbol Min Typ Max Unit
Output Voltage (T
J
= 25°C) V
O
5.88 6.0 6.12 Vdc
Output Voltage (5.0 mA I
O
1.0 A, P
D
15 W) V
O
5.76 6.0 6.24 Vdc
8.6 Vdc V
in
21 Vdc
Line Regulation (Note 2) Reg
line
mV
8.6 Vdc V
in
25 Vdc, I
O
= 500 mA 5.0 12
9.0 Vdc V
in
13 Vdc, I
O
= 1.0 A 1.4 15
Load Regulation (Note 2) Reg
load
mV
5.0 mA I
O
1.5 A, T
J
= 25°C 1.3 25
5.0 mA I
O
1.0 A 0.9 25
250 mA I
O
750 mA 0.2 15
Quiescent Current I
B
3.3 6.0 mA
Quiescent Current Change I
B
mA
9.0 Vdc V
in
25 Vdc, I
O
= 500 mA 0.8
9.0 Vdc V
in
21 Vdc, I
O
= 1.0 A, T
J
= 25°C 0.8
5.0 mA I
O
1.0 A 0.5
Ripple Rejection RR 58 65 dB
9.0 Vdc V
in
19 Vdc, f = 120 Hz, I
O
= 500 mA
Dropout Voltage (I
O
= 1.0 A, T
J
= 25°C) V
I
– V
O
2.0 Vdc
Output Noise Voltage (T
A
= 25°C) V
n
10 µV/V
O
10 Hz f 100 kHz
Output Resistance (f = 1.0 kHz) r
O
0.9 m
Short Circuit Current Limit (T
A
= 25°C) I
SC
0.2 A
V
in
= 35 Vdc
Peak Output Current (T
J
= 25°C) I
max
2.2 A
Average Temperature Coefficient of Output Voltage TCV
O
–0.3 mV/°C
ELECTRICAL CHARACTERISTICS (V
in
= 14 V, I
O
= 500 mA, T
J
= T
low
to T
high
[Note 1], unless otherwise noted.)
MC7808B MC7808C
Characteristic Symbol Min Typ Max Min Typ Max Unit
Output Voltage (T
J
= 25°C) V
O
7.7 8.0 8.3 7.7 8.0 8.3 Vdc
Output Voltage (5.0 mA I
O
1.0 A, P
D
15 W) V
O
Vdc
10.5 Vdc V
in
23 Vdc 7.6 8.0 8.4
11.5 Vdc V
in
23 Vdc 7.6 8.0 8.4
Line Regulation, T
J
= 25°C, (Note 2) Reg
line
mV
10.5 Vdc V
in
25 Vdc 6.0 160 6.0 32
11 Vdc V
in
17 Vdc 1.7 80 1.7 16
Load Regulation, T
J
= 25°C (Note 2) Reg
load
1.4 160 1.4 35 mV
5.0 mA I
O
1.5 A
Quiescent Current I
B
3.3 8.0 3.3 8.0 mA
Quiescent Current Change I
B
mA
10.5 Vdc V
in
25 Vdc 1.0
5.0 mA I
O
1.0 A 0.5 0.5
1. T
low
=0°C for MC78XXAC, C, LM340AT–XX, LM340T–XX T
high
= +125°C for MC78XXAC, C, LM340AT–XX, LM340T–XX, NCV7805
= 40°C for MC78XXB, MC78XXAB, NCV7805
2. Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.