Datasheet

Measuring length 100 - 5000 mm
CANbus protocol
24 VDC power supply
Mechanical Specifications
1 / 2
DS.DMSW.CANBUS.ENG.12.05.23.AN
L
37,5
15
6
45
11
47
40
33
ML
25
48
103
59,5
10
M5x20
50
66
65
Above given technical data are only for information purpose. OPKON has right to change product specifications without notice.
bus
Linearity
Output
Update time
Interface
Protocol
Diagnostic LEDs
Communication
100 µm
100 - 5000 mm
CANbus
max. < 5 m/s
24 VDC ±10%
Up to -30 VDC
Up to +30 VDC
1 ms (at 500 Kbit/sec)
CANbus
CAN
CiA 301, CiA 406 V 3.2
25µm (100mm-400mm), 50µm (450mm-3000mm), 100µm (4000mm-5000mm)
16 bit
Up to ±0,05% full scale (min.100 µm)
< 100 mA
(depending on stroke length)
Technical Specifications
20 (Programmable by software)
max. :1 Mbit/s (Programmable by software)
IP 65
Operating temperature
Storage temperature
Sensor Adress (Default Node ID)
Baud rate (Default :500Kbit/s)
Protection level
Green LED : Power on, CAN communication active
Red LED : Error, Stop mode
Data-length
Overvoltage protection
Power supply
Displacement speed
Max. consumption
Reverse polarity protection
Resolution
Repeatability
Measurement stroke
-20°C ... +80°C
-30°C ... +90°C
Dead Zone Calculation
DMSW (mm)
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 3000 4000 5000
1690
290 340 390 490 590 690440 540 640 740 790 840 890 940 990 1040 1090 1190 1290 1390 1490 1590 1940 2272 2522 2772 3302 4342 5342
103/47
ML
(
Measuring Length)
L
(Total Length)
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 3000 4000 5000
DMSW
Non-Contact
Magnetostrictive Position Sensor