Users Manual

OPA-3201
Specifications Manual
6
7. Environmental Specifications
7.1. Temperature
The performance is guaranteed when the range of ambient temperature is the following values:
Operating temperature : -5 ~ 50 °C
Storage temperature : -20 ~ 60
°C
7.2. Humidity
The performance is guaranteed when the range of ambient humidity is the following values:
Operating humidity : 20 ~ 85% RH (no condensation, no frost)
Storage humidity : 20 ~ 85% RH (no condensation, no frost)
7.3. Vibration Strength (without packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated
velocity of 19.6m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in the non-operating state. Repeat
this in each X, Y and Z direction.
7.4. Vibration Strength (in individual packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test:
Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated
velocity of 19.6 m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in individually packaged state.
Repeat this in each X, Y and Z direction.
7.5. Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop the scanner 18 times in total (3 times at each 6 face) from a height of 75 cm onto a
concrete floor as shown below.
Figure 4: Drop Test