User Manual

1
Baud Rate : 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control : None
UART16550 FIFO: Disable
Write Command
~
X
X
X
X
X
CR
Lead Code
Projector ID
Command
space
carriage return
Prefix
00~99
(00: All projectors)
000~999
suffix
Response Format
Pass:
P
Fail:
F
Read Command
~
X
X
X
X
X
CR
Lead Code
Projector ID
Command ID
space
carriage return
Prefix
00~99
(Default: 00)
000~999
suffix
Response Format
Pass:
O
K
n
Fail:
F
Variable
System Automatically Send
I
N
F
O
n
Fail:
F
Variable
Note : There is a <CR> after all ASCII commands. 0D is the HEX code for <CR> in ASCII code