MSDS

IDH number: 1596529 Product name: OSI SF-450 Heavy Duty Construction and Subfloor Adhesive
Page 2 of 6
3. COMPOSITION / INFORMATION ON INGREDIENTS
Hazardous components CAS NUMBER %
Limestone 1317-65-3 30 - 60
Acetone 67-64-1 10 - 30
Kaolin 1332-58-7 10 - 30
Methyl acetate 79-20-9 1 - 5
Distillates (petroleum), hydrotreated heavy naphthenic 64742-52-5 1 - 5
Titanium dioxide 13463-67-7 0.1 - 1
Quartz (SiO2) 14808-60-7 0.1 - 1
4. FIRST AID MEASURES
Inhalation:
If inhaled, immediately remove the affected person to fresh air. If breathing is
difficult, give oxygen. If not breathing, give artificial respiration. If symptoms
develop and persist, get medical attention.
Skin contact:
Rinse with running water and soap. Apply replenishing cream. Change all
contaminated clothing.
Eye contact:
In case of contact with the eyes, rinse immediately with plenty of water for 15
minutes, and seek immediate medical attention.
Ingestion:
Do not induce vomiting, seek medical advice immediately.
5. FIRE FIGHTING MEASURES
Flash point:
-17 °C (1.4 °F)
Autoignition temperature:
Not available.
Flammable/Explosive limits - lower:
Not available.
Flammable/Explosive limits - upper:
Not available.
Extinguishing media:
Foam, dry chemical or carbon dioxide. In case of fire, keep containers cool
with water spray.
Special firefighting procedures:
Wear a self-contained breathing apparatus with a full face piece operated in
pressure-demand or other positive pressure mode. Wear full protective
clothing.
Unusual fire or explosion hazards:
Closed containers may explode when exposed to extreme heat. Vapors may
form explosive mixtures with air. Vapors are heavier than air and may travel
along floor to an ignition source.
Hazardous combustion products:
Carbon dioxide. Carbon monoxide.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
personnel.
Environmental precautions:
Eliminate all sources of ignition or flammables that may come into contact with
a spill of this material. Ventilate area. Do not allow product to enter sewer or
waterways.
Clean-up methods:
Use noncombustible absorbent material such as sand. Use non-sparking tools
for clean-up. Absorb spill with inert material. Shovel material into appropriate
container for disposal. Wear suitable protective clothing, gloves and eye/face
protection.