OutBack Specifications

Worldwide Corporate Offices
North America
Tel: +1 360.435.6030
Fax: +1 360.435.6019
Europe
Tel: +49 9122.79889.0
Fax: +49 9122.79889.21
Latin America
Tel: +1 561.792.9651
Fax: +1 561.792.7157
Asia Pacific
Tel: +852 2736.8663
Fax: +852 2199.7988
AVAILABLE FROM
FXR/VFXR 60Hz/120V Specications 06/2015
Models:
Sealed Vented
FXR2012A FXR2524A FXR3048A VFXR2812A VFXR3524A VFXR3648A
Continuous Power Rating (@ 25° C)
2000VA 2500VA 3000VA 2800VA 3500 VA 3600 VA
AC Output Voltage (selectable)
120 VAC (100-130VAC) 120VAC (100-130VAC) 120VAC (100-130VAC) 120VAC (100-130VAC) 120VAC (100-130VAC) 120VAC (100-130VAC)
AC Output Frequency (selectable)
60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz)
Nominal DC Input Voltage
12VDC 24VDC 48VDC 12VDC 24VDC 48VDC
Continuous AC RMS Output (@ 25° C)
16.7AAC 20.8AAC 25AAC 23.3AAC 29.2AAC 30AAC
Idle Power
Full: ~34W
Search: ~9W
O: ~3W
Full: ~34W
Search: ~9W
O: ~3W
Full: ~34W
Search: ~9W
O: ~3W
Full: ~34W
Search: ~9W
O: ~3W
Full: ~34W
Search: ~9W
O: ~3W
Full: ~34W
Search: ~9W
O: ~3W
Typical Eciency
90% 92% 93% 90% 92% 93%
CEC Weighted Eciency
91% 90.5% 91%
Peak Eciency
95%
Total Harmonic Distortion
Typical: < 2%
Maximum: < 5%
Typical: < 2%
Maximum: < 5%
Typical: < 2%
Maximum: < 5%
Typical: < 2%
Maximum: < 5%
Typical: < 2%
Maximum: < 5%
Typical: < 2%
Maximum: < 5%
Output Voltage Regulation
± 2.5% ± 2.5% ± 2.5% ± 2.5% ± 2.5% ± 2.5%
Maximum Output Current
Peak: 56AAC
RMS: 40AAC
Peak: 70AAC
RMS: 50AAC
Peak: 70AAC
RMS: 50AAC
Peak: 56AAC
RMS: 40AAC
Peak: 70AAC
RMS: 50AAC
Peak: 70AAC
RMS: 50AAC
AC Overload Capability
Surge: 4800VA
5 Sec: 4500VA
30 Min: 2500VA
Surge: 6000VA
5 Sec: 5400VA
30 Min: 3200VA
Surge: 6000VA
5 Sec: 5400VA
30 Min: 3200VA
Surge: 4800VA
5 Sec: 4500VA
30 Min: 3200VA
Surge: 6000VA
5 Sec: 5400VA
30 Min: 4000VA
Surge: 6000VA
5 Sec: 5400VA
30 Min: 4000VA
AC Input Voltage Range (MATE3 Adjustable)
85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC
AC Input Frequency Range
54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz)
AC Input Tare Loss
0 VA 0 VA 0 VA 0 VA 0 VA 0 VA
Grid-Interactive Voltage Range
106 to 132VAC 106 to 132VAC 106 to 132VAC 106 to 132VAC
Grid-Interactive Frequency Range
59.3 to 60.5Hz 59.3 to 60.5Hz 59.3 to 60.5Hz 59.3 to 60.5Hz
AC Input Current Maximum
60AAC 60AAC 60AAC 60AAC 60AAC 60AAC
Continuous Battery Charge Output
100ADC 55ADC 35ADC 125ADC 82ADC 45ADC
Maximum Battery Charging (AC/DC/Power)
14AAC / 100ADC / 1360VA 14AAC / 55ADC / 1500VA 14AAC / 35ADC / 1900VA 18AAC / 125ADC / 1700VA 20AAC / 82ADC / 2230VA 20AAC / 45ADC / 2450VA
DC Input Voltage Range
10.5 to 17VDC 21 to 34VDC 42 to 68VDC 10.5 to 17VDC 21 to 34VDC 42 to 68VDC
Warranty
Standard 5-yr / optional 10-yr Standard 5-yr / optional 10-yr Standard 5-yr / optional 10-yr Standard 5-yr / optional 10-yr Standard 5-yr / optional 10-yr Standard 5-yr / optional 10-yr
Weight (lb/kg)
Unit: 62 / 29
Shipping: 67 / 30
Unit: 62 / 29
Shipping: 67 / 30
Unit: 62 / 29
Shipping: 67 / 30
Unit: 61 / 28
Shipping: 67 / 30
Unit: 61 / 28
Shipping: 67 / 30
Unit: 61 / 28
Shipping: 67 / 30
Dimensions H x W x L (in/cm)
Unit: 13 x 8.25 x 16.25 / 33 x 21 x 41 Shipping: 21.75 x 13 x 22 / 55 x 33 x 56 Unit: 12 x 8.25 x 16.25 / 30 x 21 x 41 Shipping: 21.75 x 13 x 22 / 55 x 33 x 56
Temperature range
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Rated: -20 to 50°C
Operating: -40 to 60°C
Storage: -40 to 60°C
Releative Humidity rating
93% 93% 93% 93% 93% 93%
Listings/certications
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex FF
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex F
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex FF
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex FF
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex FF
UL 1741, CSA C22.2 No.
107.1, UL 1778 Annex FF
RoHS Compliance
Yes Yes Yes Yes Yes Yes