Product Manual

EN pg.5
Ensure proper fall clearance is present for specic equipment being used.
NOTE: The maximum allowable free fall
distance for lanyards must not exceed six feet.
No free fall allowed for non-LE SRLs.
Class A SRLS must arrest falls within 24 inches;
Class B SRLs must arrest falls within 54 inches.
When Attaching Personal Fall Arrest
System Components to Fall Protection
Series Beam Clamp:
• Ensure the connector attached to the beam clamp
is suitable and fully compatible with the beam clamp
in use. It must be large enough that it completely
encircles the bail and locks in that position.
• Ensure the connector is not designed/oriented in
such a way as to cause excess load to be applied to
the gate of the connector.
Avoid any situation that could cause the connector
to open unexpectedly, including roll-out.
• Do not use improper connectors or misuse proper
connectors as this could cause serious injury.
Material Handling Usage
Any usage of the clamp for material handling purposes must be treated in the same way as a fall arrest.
After any type of material handling usage, the clamp must be removed from service and pass an inspection
by a qualied person prior to returning it to service as part of a personal fall arrest system.
Example Fall Clearance Calculation
18 1/2ft Total Fall Clearance Distance
6ft
Length of
Lanyard
3 1/2ft
Deceleration
Distance
6ft
Height of
Worker
3ft
Safety
Factor