Owner manual

TENANTS PHONE WIRING
The RJ71X12 and RJ71X24 are supplied by Pach and Company. The label UP or TOP must at top. Use 22-gauge
twisted wire.
RJ71X12
has 2-columns (A and B) and each column has 50 pins. Each pin is labeled (TNT-T1, TNT-R2, CO-T1, CO-
T2,......., TNT-T12, TNT-R12, CO-T12, CO-R12).
TNT is the output telephone wires (Tip and Ring) to the tenant apartment or house.
CO
is the input from telephone company wires (dial tone, tip and ring). See figure 2.3(a).
RJ71X24 has 4-columns (A B C and D) and each column has 50 pins. Each pin on column A and B are connected and
each pin on column C and D are connected.
WARNING: THE CONNECTIONS ARE NOT IN PARALLEL.
Each pin is labeled (TNT-T1, TNT-R2, CO-T1, CO-T2,......., TNT-T24, TNT-R24, CO-T24, CO-R24).
TNT is the output telephone wires (Tip and Ring) to the tenant apartment or house.
CO
is the input from telephone company wires (dial tone, tip and ring). See figure 2.3(b).
TELEPHONE STATION CONNECTOR CABLE
Connect the telephone station connector cable supplied to each relay board. The connection will restore the tenant’s
phone line. See figure 2.2, 2.3(a) and 2.3(b).
OPTIONAL HEATER PAD (AHP5)
A heater pad must be installed if the ambient temperature is below 32°F. See figure 2.3 for power connection.
Specifications: 12 VAC/12VDC 10 Watts, 55.4 °F
Step 1: Turn the system OFF.
Step 2: Install the heater pad behind the Liquid Crystal Display (LCD). Provide 1/4” - 1/2” clearance from the back of the
LCD.
Warning: Do not install the heater pad on top of the LCD without a clearance, It may damage the LCD.
Step 3: Install a duct tape on the LCD’s ribbon cable.
RS-232 CONNECTION
The AeGIS NPB9000 Series come with RS-232 DB9 Port. The port is used for local programming via AeGIS NPB9000
Series Management Software. See wiring diagram below for RS-232 connector wiring diagram.
To AC1 and AC2
on Figure 2.1
Figure 2.3
16
14
15
17
Pach and Company Chapter 2 Page 9
AeGIS NPB9000 Series INSTALLATION 05/01/02