Expansion Relay Panel DIP switches setting
The expansion relay panel is needed to configure more than 120 tenants. Each of the MX79xxx can be used to configure
additional 120 tenants. For example 168 tenants system requires MS79120 and MX79048. See table 1.1 and table 1.2 for
expansion board setting.
Table 2.2 MX79012 - MX79120 DIP SWITCHES SETTING
The Relay Correlation Number
Table 2.3 The Relay Number Correlation with 4-digit Phone Number
MX79012 - MX79120 Expansion Board Switch Setting
Expansion Board # / Switch 1 2 3 4
1 (121 - 240 tenants) OFF ON ON ON
2 (241 - 360 tenants) ON OFF ON ON
3 (361 - 480 tenants) OFF OFF ON ON
4 (481 - 600 tenants) ON ON OFF ON
5 (601 - 720 tenants) OFF ON OFF ON
6 (721 - 840 tenants) OFF OFF OFF ON
7 (841 - 960 tenants) ON ON ON OFF
Relay Relay# 4-digit Relay Relay# 4-digit Relay Relay# 4-digit
Board (LED#) Phone# Board (LED#) Phone # Board (LED#) Phone#
1 1 0001 3 1 0025 5 1 0049
1 2 0002 3 2 0026 5 2 0050
1 3 0003 3 3 0027 5 3 0051
1 4 0004 3 4 0028 5 4 0052
1 5 0005 3 5 0029 5 5 0053
1 6 0006 3 6 0030 5 6 0054
1 7 0007 3 7 0031 5 7 0055
1 8 0008 3 8 0032 5 8 0056
1 9 0009 3 9 0033 5 9 0057
1 10 0010 3 10 0034 5 10 0058
1 11 0011 3 11 0035 5 11 0059
1 12 0012 3 12 0036 5 12 0060
2 1 0013 4 1 0037
2 2 0014 4 2 0038
2 3 0015 4 3 0039 83 3 0987
2 4 0016 4 4 0040 83 4 0988
2 5 0017 4 5 0041 83 5 0989
2 6 0018 4 6 0042 83 6 0990
2 7 0019 4 7 0043 83 7 0991
2 8 0020 4 8 0044 83 8 0992
2 9 0021 4 9 0045 83 9 0993
2 10 0022 4 10 0046 83 10 0994
2 11 0023 4 11 0047 83 11 0995
2 12 0024 4 12 0048 83 12 0996
Pach and Company Chapter 2 Page 11
AeGIS NPB9000 Series INSTALLATION 05/01/02